background image

11 

 

Stop time testing 

P55 

A

项测试

 

A Testing   

0 - 2 

0

:关闭

        1

:开启

  2: 

休眠

         

0

off            1

on    2: dormancy 

P56 

B

项测试

 

B Testing   

0 - 1 

0

:关闭

      1

:开启

 

(电磁铁测试)

 

0

off          1

on (electromagnet testing)      

P57 

压脚保护开关

 

Presser foot safety switch 

0 - 1 

0

:关闭

          1

:开启

 

0

0ff              1

on 

P58 

缝台保护开关

 

Sewing plate safety switch 

0 - 1 

0

:关闭

          1

:开启

 

0

0ff              1

on 

P59 

针杆护罩保护开关

 

Needle bar cover safety switch 

0 - 1 

0

:关闭

          1

:开启

 

0

0ff              1

on 

P60 - 

 

P61 

休眠时间

   Sleeping time 

1 - 250   

30 

分钟

    Unit: minutes 

P62 

面板按键锁定

   

Panel button lock 

0 - 1 

0

:不锁定

    1

:锁定

      0

unlock   1

lock 

(

面板锁定后长按剪线键解除锁定

After the panel is locked, press the clipping button 
to unlock it 

P63 

降速开关

   

Slow down speed button 

0 - 1 

 

P64 

降速针数

   

Stitch number of slow down 
speed 

1- 800 

 

P65 

降速速度

 

The speed of slowing down 

500 - 7000 

3500 

RPM 

P66 

前传感器档位调节

 

Adjusting gear of front sensor 

1 - 180 

-- 

参数值越大,传感器电压值越大

 

The greater the parameter values.The greater the 
voltage value of the sensor 

P67 

后传感器档位调节

   

Adjusting gear of back sensor 

1 - 180 

-- 

参数值越大,传感器电压值越大

 

The greater the parameter values,The greater the 
voltage value of the sensor 

P68 

防切布传感器档位调节

 

Adjusting gear of sensor for 
anti

cutting

 the cloth 

1 - 180 

-- 

参数值越大,传感器电压值越大

 

The greater the parameter values, 
The greater the voltage value of the sensor 

P69 

计件数计数单位

 

Unit number counting 

1 - 50 

10 

执行设置剪线次数,计件数加

1  

Setting per unit trimmer number,piece count plus1 

P70 

计件数总数设定

 

Total counting setting 

1 - 9999 

100 

 

P71 

计件数计数模式

   

Counting mode 

0 - 5 

0

:关闭;

1

:升序循环计数;

2

:降序循环计数;

3

:升序计满报警;

4

:降序计满报警;

 

5

:清除计满报警

 

0

off

1

ascending cycle count

2

descending 

cycle count

3

ascending full alarm

4

descending 

full alarm

5

remove full alarm 

P72 

强制后剪线延迟针数

 

The stitches number of 
constraint back trimmer 

0 - 80 

36 

布料前剪线后离开前、后传感器且未遮住第三传
感器经过设定针数后执行后剪线。

 

Adjust the back trimmer function even the fabric 
does not cover the anti-cutting sensor, can adjust 
the stitches number before the trimmer function 
active. 

P73 

出厂默认转速参数

 

Default Speed Parameters   
 

0 - 1 

0

:四线机型默认转速

  P01=6000 P03 =5500 

0

Default speed of four thread model   

1

:五线机型默认转速

  P01=5000 P03 =5000 

1

Default speed of five thread model   

系统员参数(

P+

上键,设置三位密码进入“

111

”)

 

System member parameters (P + up button, set three passwords into "111")   

P75 

转接板报错使能

 

Transfer board error reporting 
enablement 

0 - 1 

0

:关闭;

1

:打开转接板检测功能;

 

0

off;1

Open the switch board detection function 

Summary of Contents for C5

Page 1: ...C5 V1 8 Instructions of C5 overlock sewing machine panel operation 2020 6 1 EC5...

Page 2: ...e Setting 4 2 9 LED light setting 4 2 10 Button lock setting 4 2 11 Voice quick switch 4 2 12 Sensor for anti cutting the cloth swift switch 5 2 13 Forced removal of cloth piece value 5 2 14 Fabric se...

Page 3: ...ase the number within a parameter 5 Right button control machine head LCD light brightness Towards the right to choose parameter within a parameter 6 Sewing mode button Change the sewing mode 7 Presse...

Page 4: ...be cycled as following three modes Automatic Semi automatic Full manual Press enter mode to confirm and save after finishing setting No Pressing for 5 seconds return to standby interface if user does...

Page 5: ...ter button to save and confirm after finishing setting No Pressing for 5 seconds return to standby interface if user doesn t want to save every press enter the current trimmer status firstly and cycle...

Page 6: ...ng users common parameters reset button for restoring users saving parameters before saving factory parameters are the same as users saving parameters P19 P20 version no Parameter P66 P67 P68 the duty...

Page 7: ...rameter values to change then the P28 parameter is equal to the user saves parameter values 5 When entering the other interface without saving and don t press any key for 5 seconds will automatically...

Page 8: ...h sensor enabled state changes the sensor will be automatically calibrated 2 16 Thick material voltage threshold setting 1 5 P U15 OK Er P 50 U16 PA2 1 1 5 Press the presser foot lifter for about 1 5...

Page 9: ...er values of PA0 PA1 Note Normal sewing can be done during regular maintenance reminder 2 19 Short thread mode quick switch 3s OK P27 U25 Press the short thread button for 3 seconds to switch the shor...

Page 10: ...erized 1 semi automatic 2 fully automatic P6 Voice volume adjustment 0 3 2 0 1 3 0 off 1 3 on P7 Auto trimming 0 3 3 0 1 2 3 0 off 1 trimmer before sewing 2 trimmer after sewing 3 trimmer both before...

Page 11: ...n 0 250 0 0 100 ms Time when front suction off 0 is not off 100 ms P25 Back sensor switch 0 1 1 0 1 0 off 1 on P Technician parameter At the same time press the P button and the presser foot lifter bu...

Page 12: ...r foot lifter 1 50 2 100ms P40 Start time after presser foot lifter 0 20 0 100 ms P41 Full output time of presser foot 1 50 10 10 ms P42 Periodic signal of presser foot output 0 50 15 10 ms 5MS Turn o...

Page 13: ...tage value of the sensor P68 Adjusting gear of sensor for anti cutting the cloth 1 180 The greater the parameter values The greater the voltage value of the sensor P69 Unit number counting 1 50 10 1 S...

Page 14: ...hread number closing P82 Synchronized suction back suction closed needle number 0 250 0 0 P82 0 Back suction and back trimmer synchronous closing Other when after front suction opening go by P82 threa...

Page 15: ...Unit month 0 1 500 0 not enable 1 500 reminder time P102 Base enable of thick material 0 1 0 1 1 Automatic acquisition of base value when thickness enters the threshold setting of thick material P112...

Page 16: ...function is turned off duty cycle decreases from 100 to U28 setting value uniformly in 1 U29 time duty cycle decreases from U28 to U31 setting value uniformly in 2 U29 time and 3 U28 duty cycle is con...

Page 17: ...e Please try to restore the factory settings or restart the power supply If the above can not be solved please contact the local service provider or dial 4008876858 Pressing the P key or the voice key...

Page 18: ...solve the problem please contact with the local agent or call 4008876858 E9 Pedal connection abnormal 4008876858 Please check whether the pedal plug is connecting with control box or not or loosening...

Page 19: ...Voltage foot electromagnet control fault EA1 The ascending count is full P P71 5 Press P to clear or change value to 5 in parameter P71 EA2 The descending count is full P P71 5 Press P to clear or ch...

Page 20: ...l and panel program to a matching program A 09 White grease regular maintenance warning A 10 Regular cleaning warning 7 Speed controller 1 4 ST4 8 2 Use four pieces ST4 8tapping screw Part No 2 to ins...