background image

14 

 

materials 

mode; 2: deceleration mode after bone cross sewing 

U21 

第四传感器灵敏度

 

Fourth sensor sensitivity 

200 – 400   

330 

单位

 Unit

0.01V 

U22 

第四传感器使能参数

 

Fourth sensor enabling 
parameter 

0 - 1 

 

U24 

剪线补偿功能使能参数

 

Compensation function of 
trimming enabling parameter 

0 – 1 

 

U25 

出厂针距设定

 

Out-of-factory Needle gauge 
setting  

0 – 60 

40 

单位

 Unit

0.1mm 

0

:禁用手动设定针距

     

其他:使用手动设定针

 

0: Disable manual setting of needle gauge . Others: 
Use manual setting of needle gauge   

U26 

自动补偿面料类型选择

 

Selection of automatic 
compensation fabric types   

0 - 2 

0

:针织面料;

1

:梭织面料;

2

:大针距模式

 

0

knitting fabric

1

woven fabric

2:large gauge 

mode 

U27  

压脚降噪全开时间

 

Full opening time of presser 
foot noise reduction 

1-50 2 

单位

 Unit

10ms 

U28 

压脚降噪

PWM

开启时间

PWM opening time 1 of 
presser foot noise reduction 

0-50 35 

单位

 Unit

0.1ms

,总周期

Total cycle 5ms 

U29  

压脚降噪

PWM

控制时间

 

PWM control time of presser 
foot noise reduction 

0-50 8 

单位

 Unit

10ms 

U30  

压脚降噪模式

 

Presser foot noise reduction 
mode 

0-3 0 

0-

降噪功能关闭;

1-U29

时间内占空比从

100%

U28

设定值均匀变化;

2-

U29

时间内占空比

U28

降到

U31

设定值均匀变化;

3-

U29

间内按恒定

U28

占空比

 

0-noise reduction function is turned off; duty cycle 
decreases from 100% to U28 setting value 
uniformly in 1-U29 time; duty cycle decreases from 
U28 to U31 setting value uniformly in 2-U29 time; 
and 3-U28 duty cycle is constant in U29 time.   

U31 

压脚降噪

PWM

开启时间

PWM opening time 2 of 
presser foot noise reduction 

0-50 15 

单位

 Unit

0.1ms

,总周期

Total cycle 5ms 

4.2

 

监控参数   

Monitoring parameters 

P+

右键进入监控界面

,

左右键调节监控参数项,按

P

键进入当前监控参数值。在监控参

数值界面,短按

P

键即可退出监控模式,按左右键可调节监控参数项。

 

P + right button to enter the monitoring interface, left and right button to adjust the monitoring parameters, 
press P key to enter the current monitoring parameters. In the monitoring parameter value interface, the 
monitoring mode can be withdrawn by pressing P key, and the monitoring parameter items can be adjusted by 
pressing left and right keys. 

序号

No. 

内容

 Content 

M0 

退出监控模式

    Exit monitoring mode 

M1 

当前计件数

            Current piece count       

M2 

机型类型

                Type of model 

M3 

Q

轴电流

                Q-axis current 

M4 

交流输入电压

    Ac input voltage 

M5 

踏板电压值

      Pedal voltage sampling value 

M6 

保留

                        Reserved 

M7 

前传感器电压值

    Front sensor voltage value 

M8 

中传感器电压值

    Middle sensor voltage value 

M9 

后传感器电压值

    Back sensor voltage value 

M10 

实时速度值

      Real time velocity value 

M11 

防干扰前传感器电压值(保留)

Anti-interference front sensor voltage value (reserved) 

Summary of Contents for C5

Page 1: ...C5 V1 8 Instructions of C5 overlock sewing machine panel operation 2020 6 1 EC5...

Page 2: ...e Setting 4 2 9 LED light setting 4 2 10 Button lock setting 4 2 11 Voice quick switch 4 2 12 Sensor for anti cutting the cloth swift switch 5 2 13 Forced removal of cloth piece value 5 2 14 Fabric se...

Page 3: ...ase the number within a parameter 5 Right button control machine head LCD light brightness Towards the right to choose parameter within a parameter 6 Sewing mode button Change the sewing mode 7 Presse...

Page 4: ...be cycled as following three modes Automatic Semi automatic Full manual Press enter mode to confirm and save after finishing setting No Pressing for 5 seconds return to standby interface if user does...

Page 5: ...ter button to save and confirm after finishing setting No Pressing for 5 seconds return to standby interface if user doesn t want to save every press enter the current trimmer status firstly and cycle...

Page 6: ...ng users common parameters reset button for restoring users saving parameters before saving factory parameters are the same as users saving parameters P19 P20 version no Parameter P66 P67 P68 the duty...

Page 7: ...rameter values to change then the P28 parameter is equal to the user saves parameter values 5 When entering the other interface without saving and don t press any key for 5 seconds will automatically...

Page 8: ...h sensor enabled state changes the sensor will be automatically calibrated 2 16 Thick material voltage threshold setting 1 5 P U15 OK Er P 50 U16 PA2 1 1 5 Press the presser foot lifter for about 1 5...

Page 9: ...er values of PA0 PA1 Note Normal sewing can be done during regular maintenance reminder 2 19 Short thread mode quick switch 3s OK P27 U25 Press the short thread button for 3 seconds to switch the shor...

Page 10: ...erized 1 semi automatic 2 fully automatic P6 Voice volume adjustment 0 3 2 0 1 3 0 off 1 3 on P7 Auto trimming 0 3 3 0 1 2 3 0 off 1 trimmer before sewing 2 trimmer after sewing 3 trimmer both before...

Page 11: ...n 0 250 0 0 100 ms Time when front suction off 0 is not off 100 ms P25 Back sensor switch 0 1 1 0 1 0 off 1 on P Technician parameter At the same time press the P button and the presser foot lifter bu...

Page 12: ...r foot lifter 1 50 2 100ms P40 Start time after presser foot lifter 0 20 0 100 ms P41 Full output time of presser foot 1 50 10 10 ms P42 Periodic signal of presser foot output 0 50 15 10 ms 5MS Turn o...

Page 13: ...tage value of the sensor P68 Adjusting gear of sensor for anti cutting the cloth 1 180 The greater the parameter values The greater the voltage value of the sensor P69 Unit number counting 1 50 10 1 S...

Page 14: ...hread number closing P82 Synchronized suction back suction closed needle number 0 250 0 0 P82 0 Back suction and back trimmer synchronous closing Other when after front suction opening go by P82 threa...

Page 15: ...Unit month 0 1 500 0 not enable 1 500 reminder time P102 Base enable of thick material 0 1 0 1 1 Automatic acquisition of base value when thickness enters the threshold setting of thick material P112...

Page 16: ...function is turned off duty cycle decreases from 100 to U28 setting value uniformly in 1 U29 time duty cycle decreases from U28 to U31 setting value uniformly in 2 U29 time and 3 U28 duty cycle is con...

Page 17: ...e Please try to restore the factory settings or restart the power supply If the above can not be solved please contact the local service provider or dial 4008876858 Pressing the P key or the voice key...

Page 18: ...solve the problem please contact with the local agent or call 4008876858 E9 Pedal connection abnormal 4008876858 Please check whether the pedal plug is connecting with control box or not or loosening...

Page 19: ...Voltage foot electromagnet control fault EA1 The ascending count is full P P71 5 Press P to clear or change value to 5 in parameter P71 EA2 The descending count is full P P71 5 Press P to clear or ch...

Page 20: ...l and panel program to a matching program A 09 White grease regular maintenance warning A 10 Regular cleaning warning 7 Speed controller 1 4 ST4 8 2 Use four pieces ST4 8tapping screw Part No 2 to ins...