DAILY MAINTENANCE
ENGINE:
1. Check oil level. Add oil if oil level is at or below add mark.
2. Check fan for damage and fan belt for proper tension.
3. Empty dust discharge valve.
4. Check Air Filter (see page 15 &16 for details).
5. Check General condition of engine for leaks or damage parts, worn or damaged
Belts and any change of engine appearance.
CHASSIS:
6. Check hydraulic oil level. If hydraulic oil is low add ONLY ISO – 68 hydraulic oil.
DO NOT add motor oil to hydraulic oil.
7. Check fuel level.
8. Check conveyor belt tension. The conveyor belts must be tight enough to carry a full
load without slipping.
9. Start engine at idle. Idle for 2 – 3 minutes to warm up oil and engine.
10. Start conveyor belts at low speed and check tracking. All conveyor belts should
track in center of pulleys. Then run conveyor belts at full speed and check tracking.
11. Check the general condition of the elevator for hydraulic leaks and worn or damaged
parts.
16