CONNECTION OF THE TANK VALVE PER ANSIZ21.81.
1. Make sure tank valve is in its full off position (turn clockwise to stop).
2. Check tank valve to assure it has proper external male threads (type I connection per ANSIZ21.81).
3. Make sure all burner knobs are in their off position.
4. Remove the protective cap from L.P. tank valve. Always use cap and strap supplied with valve.
5.
Inspect valve connection port and regulator assembly. Look for any damage or debris. Remove
any debris. Inspect hose for damage. Never attempt to use damaged or plugged equipment.
Contact your local L.P. gas dealer for repair.
6.
When connect regulator assembly to the valve, hand tighten nut clockwise to a positive stop. Do
not use a wrench to tighten. Use of a wrench may damage quick coupling nut and result in a
hazardous condition. (as the figure shown below)
7.
Open tank valve fully (counterclockwise). Use a soapy water solution to check all connections for
leaks before attempting to light grill. If a leak is found, turn tank valve off and do not use grill until a
local L.P. gas dealer can make repairs.
OPD HAND WHEEL
g
!!!
WARNING
!!!
2. Never insert any foreign objects into the valve outlet. It may damage the valve
and cause leak, leaking gas may result in fire, explosion, heavy body injury, or
even death.
3. Do not connect this grill to the self-contained
L.P.
gas system of a motor home or
camper trailer.
4. Do not use the grill until leak tested.
5. Stop and call the fire department if any leak detected.
6. If you cannot stop a gas leak, close the L.P. tank valve IMMEDIATELY, call L.P.
supplier or the fire department.
!!!
DANGER
!!!
1. NEVER store a spare L.P. tank under or near grill or in an enclosed area.
2. NEVER fill the tank beyond 80% full. An overfilled spare L.P. tank is dangerous
because surplus gas may leak from safety relief valve. The safety relief valve on
a L.P. tank could activate to release gas and cause a fire.
3. The spare L.P. tank must have safety caps installed on the L.P. tank outlet.
4. If any gas leak found on the spare L.P. tank, immediately go away from it and call
the fire department.
15
Summary of Contents for Classic PG-50403SRL
Page 6: ...EXPLODED VIEW 6 ...
Page 11: ...5 6 7 8 9 10 11 ...