SERVICE PROCEDURES continued
Most problems are buildup of water deposits on bonnet. Install repair kit - DO NOT REPLACE ENTIRE VACUUM
BREAKER.
(1) WARNING: DISCONNECT THE ELECTRICAL POWER TO THE DISHWASHER AT THE MAIN CIRCUIT
BOX. PLACE A TAG ON THE CIRCUIT BOX INDICATING THE CIRCUIT IS BEING WORKED ON.
(2) Turn water supply off to dishwasher.
(3) Remove cap from vacuum breaker which is secured by (1) screw.
(4) Unscrew top using screwdriver.
(5) Install all repair kit parts.
(6) Reassemble in reverse order.
(7) Turn water supply on to dishwasher.
(8) Dishwasher is ready 10 use.
12. To replace the temperature gauges.
The thermometers are NSF approved gauges to be accurate /- 3 Deg. F. Check them periodically
with a calibrated thermometer to insure proper wash and rinse temperatures.
WARNING: DISCONNECT THE ELECTRICAL POWER TO THE DISHWASHER AT THE MAIN CIRCUIT BREAKER.
TAG CIRCUIT BREAKER TO INDICATE THE CIRCUIT IS BEING REPAIRED.