4
Option
Description
Zone number
Range
Range
Range
Range
Range
Range
Range
Range
Range
Range
Range
Range
Range
Range
01 to 08
01 to 32
00- G/E 01- Heat Pump
01 to 09 minutes
60 to 85F
02 to 06F
01 to 04F
01 to 10F
01 to 12F
0 = OFF 1 = ON
00- Off 01- On
55 to 80F
00- Gas 01- Electric
01 to 09 minutes
Default
Default
Default
Default
Default
Default
Default
Default
Default
Default
Default
Default
Default
Default
01
01
00- G/E
00 minutes
85F
02F
01F
03F
05F
0
01- On
65F
00- Gas
00 minutes
Home number
Program HVAC module with Zone
and Home address - Default 01
Equipment type
Indoor Fan Operation
Minimum Off Time
Minimum Run Time
Maximum allowable heating setpoint
Minimum allowable cooling setpoint
Heat/Cool Setpoint Differential
Stage 1 Temperature Differential
Stage 2 Temperature Differential
Stage 3 Temperature Differential
Staging Time
Automatic Backup
01
02
03
04
05
06
07
08
09
10
11
12
13
14
16
Thermostat Installer Options
7
Use the
Up
and
Down
keys to set the
Zone
number for the each thermostat. The
Zone
number can be set from 01 to 08.
Zone Numbers can be used to identify individual
thermostats. Press the
NEXT
key to advance to
the next option. Press the
ENTER
key if no more
options are to be changed.
Option
Zone
CANCEL
NEXT
ENTER
Setting the Zone Number
Press the
NEXT
key to select
Option
02
. The
Home
number is used to distinguish between
thermostats and HVAC Control Modules that are
less than 500 feet away from one another. This
could be a home with two HVAC systems or a
multi-family residence.
Setting the Home number
The installer options can be accessed by
pressing and holding the
ENTER
key for seven
seconds. The LCD displays Option 01 for setting
the
Zone
number. (See Installer Options Chart)
Press or hold the
NEXT
key to advance to the
next option. The LCD will advance through to
Option 16 and then return to Option 01.
Press the
ENTER
key to save all options in non-
volatile flash ram.
If only one wireless thermostat and HVAC Control
Module are used in an application, the thermostat
can be left with the factory default setting of
Zone
= 01
and
Home = 01.
If multiple wireless thermostats and HVAC
Control Modules are used that are less than 500
feet away from one another, each thermostat
must be set to a different
Home
number. For
convenience, set the Installer Options with the
thermostat off the subbase and in easy access of
its HVAC Control Module.
Installer Options Chart
8
9
Range
15 - 30 (1 Minute Increments)
Default
15
Staging Time When 14 = 1 (ON)
15
Range
40 - 95
Default
Factory Calibrated
Temperature Calibration
17