background image

Installation Manual

Model WCT-32

SYSTEM

FAN

The WCT-32 is a 7-day programmable, battery
powered thermostat that communicates via an
RF wireless data link to a relay control module
located near the HVAC equipment.

The WCT-32 can control single stage, multi-
stage and heat pumps with up to 3 stages of
heating and 2 stages of cooling.

Manual or programmable selection with up
to four schedules per day.

Exclusive Memory Backup insures reliable
performance in the event of a
communications interruption.

Wireless 915MHz proprietary protocol with
up to 100’ transmission range.

Easy access, front-loading battery
compartment. 2 AA batteries included.

Application

Features

Compatible Equipment

Output Terminals

Fan Operation

LED Indicator

Communications

Range

Control Module Power

Control Module Housing

Control Module Dimensions

Thermostat Dimensions

Single stage, multi-stage and heat pumps (3 heat / 2 cool)

W1/B, O, W2/E, Y1, Y2, G

Gas or electric

Multi-color indicates heating, cooling and fan calls

Wireless, 915MHz, proprietary protocol

Up to 100 feet

24VAC, 2.4VA

Molded plastic

5.09 x 2.65 x 1.10 inches (WHD)

5.00 x 4.50 x 1.00 inches (WHD)

Wireless

COMF RT

TM

Made in the USA

Specifications

Summary of Contents for Wireless Comfort WCT-32

Page 1: ...terruption Wireless 915MHz proprietary protocol with up to 100 transmission range Easy access front loading battery compartment 2 AA batteries included Application Features Compatible Equipment Output...

Page 2: ...s are included or the module can be installed with double backed adhesive tape 1 COM COM Gas Electric HVAC System Heat Pump System R R Y1 Y1 Y2 Y2 W2 W2 E O W1 B G G Wiring Heat Pump up to 3 heat 2 co...

Page 3: ...l Avoid placing the thermsotat in areas where the air movement is limited affected by direct sunlight or other areas not typical of the temperature in the space Location 3 The thermostat should be ins...

Page 4: ...next option Press the key if no more options are to be changed NEXT ENTER Option Zone CANCEL NEXT ENTER Setting the Zone Number Press the key to select T NEXT Option 02 he number is used to distinguis...

Page 5: ...ey to select 00 Gas Electric or 01 Heat Pump operation NEXT Option 04 Up Down 11 Set To Fan Operation Press the key to select The fan can be set to 00 Gas operation where the equipment activates the H...

Page 6: ...un Time NEXT Option 07 Up Down Option CANCEL NEXT ENTER 15 Heating Setpoint Limit The maximum heating setpoint the user can set is 60 to 85F Press the key to select and press the or key to set maximum...

Page 7: ...tage temperature differential the equipment activates second stage heating or cooling Press the key to select and the or key to set the second stage temperature differential If the first stage tempera...

Page 8: ...conjunction with the supplied User Manual Although great care has been taken in preparation of this manual Jackson Systems takes no responsibility for errors or omissions contained herein It is the re...

Reviews: