GENERAL INSTALLATION
INSTRUCTIONS of
MACHINE DRAIN LINE
STEP 1: LOCATION OF DRAIN LINE CONNECTION Note:
Refer to Drawing A-1.
The drain line connection on this machine is located at rear of machine in the upper-right-hand comer.
Connection size is 3/4“. Use 3/4" reinforced hose.
STEP 2: DRAIN LINE INSTALLATION Note:
Refer to Drawing A-2.
Drain should slope downward on an incline to customer's drain connection. For every 24 inches of drain line,
the drop should be 3" to 4".
Please reference Drawing A-3 to note the IMPROPER drain line installation. Once the drain line is sloping
downward, DO NOT slope the drain line upward again. Doing this would prevent the pump from draining
properly.
DRAIN LINE INSTALLATION FOR MODEL 24BP OR 24AP
DRAWING A-10