background image

Performance/Capacities

Conveyor

s

AJ-64 Vision Series

• 287 racks per hour hi-temp sanitizing

rinse

• 0.77 gallons per rack hi-temp sanitizing

rinse

• Incoming water pressure regulator

• Exclusive Adjust-A-Peak feature

(patented) allows the owner operator
to manually adjust the speed of the
conveyor system from 144 racks per
hour all the way to maximum capacity
of 287 racks per hour.

• Standard 25” clearance allows

owner operators the ability to wash
large utensils, trays, and bun pans.

• Totally electro-mechanical;  no solid

state controls utilized.

• Fully automatic including auto-fill.

• Completely self-draining, stainless

steel wash and recirculating rinse
pumps.

• Exclusive “Energy Guard” controls

system energizes wash, recirculating
rinse, and final rinse sections only
when a rack is in place.

• Convenient, externally operated 

lever drains.

• Stainless steel frame, legs, adjustable

bullet feet, and front appearance
panel are all standard.

• Standard 8” vent cowls/splash

shields on both wash and rinse ends
of the machine.

• Heavy gauge construction for extra

ruggedness and durability.  

Standard Features

Operating Capacity

Racks per hour

287

Dishes per hour

7200

Glasses per hour

7200

Steam Coil Tank Heat

Steam Connection IPS (Inches)

3/4

Steam Flow Pressure (PSIG)

10-20

Consumption @ 15 PSIG (Lbs/hr) 100

Wash Pump Motor HP

2

Wash Pump Capacity (GPM)

270

Wash Tank KW

15

Conveyor Motor Horsepower

1/4

Conveyor Speed (Feet/minute)

8.0

Operating Temperatures

Wash Tank–°F (Minimum)

150

Power Rinse–°F (Minimum)

160

Rinse–°F (Minimum)

180

Dimensions

(Inches)

Length between dishtables

64

Machine width

25

Wall Clearance (Minimum)

4.5

Cavity/dish clearance (Maximum)

25

Shipping Information

Weight (Lbs)

890

Dimensions (Inches) 

Length

96

Depth

40

Height

78

Volume (Cubic feet)

174.0

Approximate Total Load

AMPS

208V / 60HZ / 3PH

81.8

208V / 60HZ / 1PH

138.9

230V / 60HZ / 3PH

75.1

230V / 60HZ / 1PH

127.5

460V / 60HZ / 3PH

37.6

Booster Heater Options

External 40°F Min. Rise

KW

AMPS

208V / 60HZ / 3PH

34.5

95.8

230V / 60HZ / 3PH

36

90.5 

460V / 60HZ / 3PH

36

45.2

External 70°F Min. Rise

KW

AMPS

208V / 60HZ / 3PH

45

125.0 

230V / 60HZ / 3PH

45

108.0

460V / 60HZ / 3PH

45

54.0

Venting Requirements (CFM)

Input end

200 

Output end

400

Total CFM

600

Water Requirements

Incoming Wash Tank Temperature (°F)

180

With 36 KW booster heater option (°F)

140

With 45 KW booster heater option (°F)

110

Gallons per hour 

222

Gallons per rack

0.77

Wash Tank Capacity (Gallons)

15.4

Incoming Waterline Size (IPS) (Minimum)

3/4

Flow Pressure (PSI)

15-25

Flow Rate Minimum (GPM)

3.7

Drainline Size IPS (Minimum) (Inches)

1 1/2

Power/Connections

Summary of Contents for AJ-64CE

Page 1: ...hour 7200 Steam Coil Tank Heat Steam Connection IPS Inches 3 4 Steam Flow Pressure PSIG 10 20 Consumption 15 PSIG Lbs hr 100 Wash Pump Motor HP 2 Wash Pump Capacity GPM 270 Wash Tank KW 15 Conveyor Motor Horsepower 1 4 Conveyor Speed Feet minute 8 0 Operating Temperatures Wash Tank F Minimum 150 Power Rinse F Minimum 160 Rinse F Minimum 180 Dimensions Inches Length between dishtables 64 Machine wi...

Page 2: ...e baked on food soil or increase the speed of the con veyor drive unit when maximum capacity is required By slowing down the conveyor a rack of tableware remains in the prewash wash and rinse sections for longer periods of time When soil loads are heavy i e pots and pans trays and bun pans adjusting the conveyor to slower speeds means outstanding results CHAMBER The chamber has a standard clearanc...

Page 3: ...NAL ELECTRIC BOOSTER HEATER External 36 KW Hatco booster heater boosts incoming 140 F water to a minimum of 180 F for hi temp sanitiz ing rinse Custom features include castone lined tank low water cutoff pressure relief valve as well as a pres sure reducing valve Unit is located next to the output end of the machine completely preplumbed Power to the booster heater requires a separate electrical c...

Page 4: ...ine available in 12 0 length ______ Table limit switch completely prewired and extending from the output end of the machine available in 15 0 length ______ Installed 4 x 16 x 7 high vent cowl collars for easy connection to an external exhaust system and including adjustable and lock able damper flaps ______ output end only ______ input end only ______ both ends ______ Incoming water hammer arresto...

Page 5: ...Connection 1 I P S G Condensate Return 1 I P S Notes All vertical dimensions are 1 2 from floor due to adjustable bullet feet Utility connections are identical for either direction of operation Left to Right or Right to Left Operation Shown 1 7 8 A Rear of Machine 8 12 67 1 2 84 w Doors Open D B E C G F D A E 62 1 2 29 Drive Unit 7 10 32 3 4 25 10 3 8 10 5 20 34 75 1 2 80 Overall 64 Table to Table...

Page 6: ... AJ 64CE AJ 64CS 208 60 1 138 9 18 8 230 60 1 127 5 18 8 208 60 3 81 8 12 3 230 60 3 75 1 12 3 460 60 3 37 6 6 2 Recommended Table Fabrication 07610 002 66 79 All specifications subject to change without notice Rack Rail Height Above Dishtable 1 4 5 16 Rack Rail Tub Table Use Silicone Sealer Between Table and Lip of Machine to Prevent Leakage Tub Will Accept a Table Flange Up to 24 7 8 Table Turnd...

Reviews: