Performance/Capacities
Conveyor
s
AJ-64 Vision Series
• 287 racks per hour hi-temp sanitizing
rinse
• 0.77 gallons per rack hi-temp sanitizing
rinse
• Incoming water pressure regulator
• Exclusive Adjust-A-Peak feature
(patented) allows the owner operator
to manually adjust the speed of the
conveyor system from 144 racks per
hour all the way to maximum capacity
of 287 racks per hour.
• Standard 25” clearance allows
owner operators the ability to wash
large utensils, trays, and bun pans.
• Totally electro-mechanical; no solid
state controls utilized.
• Fully automatic including auto-fill.
• Completely self-draining, stainless
steel wash and recirculating rinse
pumps.
• Exclusive “Energy Guard” controls
system energizes wash, recirculating
rinse, and final rinse sections only
when a rack is in place.
• Convenient, externally operated
lever drains.
• Stainless steel frame, legs, adjustable
bullet feet, and front appearance
panel are all standard.
• Standard 8” vent cowls/splash
shields on both wash and rinse ends
of the machine.
• Heavy gauge construction for extra
ruggedness and durability.
Standard Features
Operating Capacity
Racks per hour
287
Dishes per hour
7200
Glasses per hour
7200
Steam Coil Tank Heat
Steam Connection IPS (Inches)
3/4
Steam Flow Pressure (PSIG)
10-20
Consumption @ 15 PSIG (Lbs/hr) 100
Wash Pump Motor HP
2
Wash Pump Capacity (GPM)
270
Wash Tank KW
15
Conveyor Motor Horsepower
1/4
Conveyor Speed (Feet/minute)
8.0
Operating Temperatures
Wash Tank–°F (Minimum)
150
Power Rinse–°F (Minimum)
160
Rinse–°F (Minimum)
180
Dimensions
(Inches)
Length between dishtables
64
Machine width
25
Wall Clearance (Minimum)
4.5
Cavity/dish clearance (Maximum)
25
Shipping Information
Weight (Lbs)
890
Dimensions (Inches)
Length
96
Depth
40
Height
78
Volume (Cubic feet)
174.0
Approximate Total Load
AMPS
208V / 60HZ / 3PH
81.8
208V / 60HZ / 1PH
138.9
230V / 60HZ / 3PH
75.1
230V / 60HZ / 1PH
127.5
460V / 60HZ / 3PH
37.6
Booster Heater Options
External 40°F Min. Rise
KW
AMPS
208V / 60HZ / 3PH
34.5
95.8
230V / 60HZ / 3PH
36
90.5
460V / 60HZ / 3PH
36
45.2
External 70°F Min. Rise
KW
AMPS
208V / 60HZ / 3PH
45
125.0
230V / 60HZ / 3PH
45
108.0
460V / 60HZ / 3PH
45
54.0
Venting Requirements (CFM)
Input end
200
Output end
400
Total CFM
600
Water Requirements
Incoming Wash Tank Temperature (°F)
180
With 36 KW booster heater option (°F)
140
With 45 KW booster heater option (°F)
110
Gallons per hour
222
Gallons per rack
0.77
Wash Tank Capacity (Gallons)
15.4
Incoming Waterline Size (IPS) (Minimum)
3/4
Flow Pressure (PSI)
15-25
Flow Rate Minimum (GPM)
3.7
Drainline Size IPS (Minimum) (Inches)
1 1/2
Power/Connections