Specifications
Conveyors
w w w. j a c k s o n m s c . c o m
1 - 8 8 8 - 8 0 0 - 5 6 7 2
AJ-64 Vision Series
Note: Check and/or copy all that apply.
AJ-64 Series Rack Conveyor Dishwasher — Item No. ____________
Shall be a Jackson AJ-64 Series, multiple tank rack conveyor dishwasher.
Sanitization shall be accomplished by using hi-temp (180°F minimum)
sanitizing rinse.
Electrical characteristics shall be:
______ 208V/60HZ/3PH
______ 208V/50HZ/3PH
______ 208V/60HZ/1PH
______ 208V/50HZ/1PH
______ 230V/60HZ/3PH
______ 230V/50HZ/3PH
______ 230V/60HZ/1PH
______ 230V/50HZ/1PH
______ 460V/60HZ/3PH
Wash tank heating shall be a minimum of 150°F for hi-temp applications
and accomplished by:
______ 10 KW (total 20 KW) electric heating element
thermostatically controlled.
______ Stainless steel steam coils thermostatically controlled.
Direction of rack flow shall be (when standing in front of machine):
______ Right-to-Left
______ Left-to-Right
______ External Hatco 36 KW booster heater for a minimum 40°F rise
and available in the following voltages:
______ 208V/50 or 60HZ/3PH
______ 240V/50 or 60HZ/3PH
______ 480V/50 or 60HZ/3PH
______ External Hatco 45 KW booster heater for a minimum 70°F rise
and available in the following voltages:
______ 208V/50 or 60HZ/3PH
______ 240V/50 or 60HZ/3PH
______ 480V/50 or 60HZ/3PH
______ Steam booster heater.
______ Table limit switch completely prewired and extending from the
output end of the machine, available in 9’0” length.
______ Table limit switch completely prewired and extending from the
output end of the machine, available in 12’0” length.
______ Table limit switch completely prewired and extending from the
output end of the machine, available in 15’0” length.
______ Installed 4" x 16" x 7" high vent cowl collars for easy connection
to an external exhaust system and including adjustable and lock-
able damper flaps.
______ output end only
______ input end only
______ both ends
______ Incoming water hammer arrestor completely installed.
______ Sideloader installed on input end of machine.
______ unhooded sideloader
______ hooded sideloader
______ Exhaust fan control controls external exhaust fan power and
duration time.
______ Flanged feet for permanent in-place mounting to the floor.
• Capacity of 288 racks per hour
utilizing 0.77 gallons of water per
rack for hi-temp sanitizing rinse.
• Incoming water pressure regulator.
• Adjust-A-Peak conveyor drive
system to manually adjust rack
capacity of the machine.
• Minimum 25" clearance
throughout machine.
• Exclusive “Energy Guard”
controls system energizes wash,
recirculating rinse, and final
rinse sections only when a rack
is in place.
• Completely electro-mechanical;
no solid-state controls.
• Fully automatic operation includ-
ing auto-fill.
• Completely self draining, stain-
less steel wash and recirculating
rinse pumps.
• Convenient, externally operated
lever drains.
• Vent cowls/splash shields with
extra curtains on both wash and
rinse ends of the machine.
• Stainless steel frame, legs,
adjustable bullet feet, and front
appearance panel.
• All 304 series stainless steel
construction; no 400 series
stainless steel and no plastics
utilized.
Unit shall have the following features as optional extras:
Unit shall have the following features:
07610-002-66-78
All specifications subject to change without notice.