AJX-44 & AJX-54 Series Technical Manual 7610-003-60-98
Issued: 01-19-2009 Revised: 01-30-2009
SECTION 5: PARTS SECTION
HEATER BOX ASSEMBLY (CONTINUED)FRAME ASSEMBLY/DRESS PANELS
47
THERMOSTATS
The thermostat range is from 140
F to 240
F with a maximum bulb exposure temperature of 300
F.
Calibration:
Wash Thermostat:
Set Point: 165
F (Adjustable range)
Hi-LImit Thermostat:
Fixed set point: 210
F (Non-adjustable)
The hi-limit thermostat is used to protect the heater element in the event of a run away regulating thermostat or a dry fire situ-
ation. It is set for 210
F +0
F or -10
F with a fixed set point.
This part is not adjustable.
The wash tank regulating thermostat will maintain the correct wash water temperature to meet NSF requirements. These spec-
ify that the wash be no lower than 140
F on chemical sanitizing models and no lower than 160
F on hot water sanitizing
machines.
Bullet Feet (4 per model) - order using part number 05340-011-71-74.
FRONT DRESS PANELS
Model
Left to Right Part Number
Right to Left Part Number
AJX-44
05700-002-52-77
05700-002-52-77
AJX-66
05700-002-51-22
05700-002-57-84
AJX-80
AJX-54
05700-002-63-12
05700-002-63-12
AJX-76
AJX-90
Summary of Contents for AJX-44 Series
Page 8: ...1 SECTION 1 SPECIFICATION INFORMATION ...
Page 27: ...20 SECTION 2 INSTALLATION OPERATION INSTRUCTIONS ...
Page 38: ...31 SECTION 3 PREVENTATIVE MAINTENANCE ...
Page 42: ...35 SECTION 4 TROUBLESHOOTING SECTION ...
Page 45: ...38 SECTION 5 PARTS SECTION ...
Page 92: ...85 SECTION 6 ELECTRICAL SCHEMATICS ...
Page 103: ...96 SECTION 7 JACKSON MAINTENANCE REPAIR CENTERS ...
Page 110: ...AJ 44T Series Technical Manual 7610 003 07 21 Issued 03 21 2006 Revised N A ...