AJX-44 & AJX-54 Series Technical Manual 7610-003-60-98
Issued: 01-19-2009 Revised: 01-30-2009
SECTION 5: PARTS SECTION
DRAIN QUENCH SYSTEM
58
ITEM
QTY
DESCRIPTION
Mfg. No.
1
1
Thermostat
05930-121-67-72
2
1
Thermostat Bracket
05700-011-81-64
3
1
Solenoid Valve
04810-100-09-18
4
2
Nipple, Close, 1/2” NPT, Brass
04730-207-15-00
5
1
Valve, Check, 1/2”
04820-002-55-77
6
1
Reducer, 1-1/2” to 1/2”
04730-002-55-75
7
2
Tee, 1-1/2” x 1-1/2” x 1-1/2”
04730-011-69-93
8
2
Nipple, 1-1/2”, Close, Brass
04730-207-40-00
9
1
Reducer, 1-1/2” to 1/4”
04730-002-55-76
10
1
Modified Compression Fitting
05700-001-16-52
1
Complete Kit
06401-002-44-07
To Dishmachine Drain
To Drain
To Cold Water Supply
1
2
3
4
5
4
6
7
8
7
8
9
10
From the existing drain, attach the two additional Tees (Item 7) using the 1-1/2” NPT Close Nipples (Item 8). Tighten the
Reducers (Items 6 & 9) into the Tees as shown above. Attach the Modified Compression Fitting (Item 10) into the 1-1/2” to 1/4”
Reducer (Item 9). Position the bulb of the thermostat (Item 1) so that it rests approximately 1/4” from the bottom of the Tee (Item
7). Tighten the Modified Compression Fitting (Item 10) as required.
Mount the Thermostat (Item 1) to the tub using the Thermostat Bracket (Item 2) and set it for 120°F - 140°F. Install the Solenoid
Valve (Item 3) to the second Tee (Item 7) and then attach to the incoming cold water line. Use pipe dope or thread tape as
required to prevent any leaks.
Summary of Contents for AJX-44 Series
Page 8: ...1 SECTION 1 SPECIFICATION INFORMATION ...
Page 27: ...20 SECTION 2 INSTALLATION OPERATION INSTRUCTIONS ...
Page 38: ...31 SECTION 3 PREVENTATIVE MAINTENANCE ...
Page 42: ...35 SECTION 4 TROUBLESHOOTING SECTION ...
Page 45: ...38 SECTION 5 PARTS SECTION ...
Page 92: ...85 SECTION 6 ELECTRICAL SCHEMATICS ...
Page 103: ...96 SECTION 7 JACKSON MAINTENANCE REPAIR CENTERS ...
Page 110: ...AJ 44T Series Technical Manual 7610 003 07 21 Issued 03 21 2006 Revised N A ...