07610-003-92-84-T
16
CYCLE TIMER INSTRUCTIONS
INSTALLATION
1. Press and hold CYCLE COUNT button and DOWN ARROW button (under STEP
START TIME) simultaneously for 3–4 seconds.
2. Press and hold the DRAIN button. The DRAIN output stays on while the button
is held. The output turns off when the button is released. Repeat for the other
seven buttons (use SAVE/EXIT to activate CYCLE output, use CYCLE COUNT
to activate PUMP output). Second row of display shows outputs and inputs that
are active.
3.
Plant test mode can also be used to prime chemicals if the machine has no
priming function. Open door and press and hold the SANI button until sanitizer
is seen entering the wash sump/tank and no air is in the line.
4.
Repeat for DETER and RINSE AID buttons.
SELECT CYCLE STEP TO ADJUST PRESS SAVE TO EXIT
CYCLE PUMP DRAIN FILL SANI DETER SPARE
CYCLE
COUNT
SAVE
EXIT
START
TIME
DURATION
TIMER
MODEL
SELECT MODEL
RINSE
AID
STEP
STEP
DISH
CYCLE
TIMER
PLANT TEST MODE
SELECT CYCLE STEP TO ADJUST PRESS SAVE TO EXIT
CYCLE PUMP DRAIN FILL SANI DETER SPARE
CYCLE
COUNT
SAVE
EXIT
START
TIME
DURATION
TIMER
MODEL
SELECT MODEL
RINSE
AID
STEP
STEP
DISH
CYCLE
TIMER
Outputs
Cycle
Wash
Drain
Fill
Sani
Deter
Rinse
Spare
Inputs
DoorClosed
Start
After 15 seconds of no
button being pressed,
the timer exits
the plant test mode.
If more than one input
is on, the first letters
of each will show
(e.g. "Drain-DH" indicates
the DRAIN output and
DoorClosed and Heavy
inputs are on).
PLANT TEST
Drain-DoorClosed
SELECT CYCLE STEP TO ADJUST PRESS SAVE TO EXIT
CYCLE PUMP DRAIN FILL SANI DETER SPARE
CYCLE
COUNT
SAVE
EXIT
START
TIME
DURATION
TIMER
MODEL
SELECT MODEL
RINSE
AID
STEP
STEP
DISH
CYCLE
TIMER
PLANT TEST
Deter-Start
PLANT TEST
-DoorClosed
Summary of Contents for CONSERVER XL HH
Page 61: ...07610 003 92 84 T 53 XL E LTH BOOSTER TANK PARTS 16 ...
Page 65: ...07610 003 92 84 T 57 SCHEMATICS XL E XL HH 115 V 60 HZ 1 PHASE ...
Page 66: ...07610 003 92 84 T 58 SCHEMATICS XL E XL HH 208 V 60 HZ 1 PHASE ...
Page 67: ...07610 003 92 84 T 59 SCHEMATICS XL E LTH 208 230 V 60 HZ 1 3 PHASE ...
Page 68: ...07610 003 92 84 T 60 SCHEMATICS XL E FL 115 V 60 HZ 1 PHASE ...
Page 69: ......