3
07610-003-78-18-N
E1
MAIN ELECTRICAL CONNECTION (1.375” DIA HOLE)
E2
BOOSTER HEATER ELECT. CONNECTION (1.375" DIA)
W1
MAIN INLET WATER CONNECTION (1/2 NPT-F)
W2
PRE-WASH INLET WATER CONN. (1/2 NPT-F)
W3***
PRE-WASH COLD WATER CONN. (1/2 NPT-F)
D1
DRAIN CONNECTION, WASH (1-1/2" NPT-F)
D2
DRAIN CONNECTION, PRE-WASH (1-1/2" NPT-F)
DET
DETERGENT BULKHEAD ACCESS (.875" DIA HOLE)
SAN**
SANITIZER INLET TO RINSE (1/8" NPT-F)
RA
RINSE AID CONNECTION TO RINSE (1/8" NPT-F)
CP
CONDUCTIVITY PROBE ACCESS (.875" DIA HOLE)
S*
STEAM TO WASH TUB HEATING COIL (3/4" NPT-F)
C*
CONDENSATE RETURN (3/4" NPT-F)
VI
VENTILATION DUCT CONN. (LOAD END) 4" x 16" ID
V2
VENTILATION DUCT CONN. (UNLOAD END) 4" x 16" ID
15
1
4 in
67
1 2
in
63
5
8 in
64
1 2
in
73
8 in
61
1 8
in
2312 in
21 in
1118 in
414 in
7312 in MIN
(NOTE 2)
63
1 2
in
61 i
n
107 8 in
34 i
n
11
1 2
in
23
3
4 in
33 in
1718 in
3312 in
75 8 in
1412 in
618 in
9 i
n
83
4 in
83
4 in
205 8 in
20 i
n
93 i
n M
A
X
(N
O
T
E
1)
3
8 in
9 i
n
21
4 in
14
7
8 in
21
1
2 in
26
5
8 in
30
5
8 in
TABLE to TABLE
66 in
8512 in
14 i
n
16
5
8 in
20
3
8 in
14
7
8 in
W2
W3***
W1
SAN**
D1
C*
S*
RA
D2
E1
E2
W3***
W2
E1
E2
W1
RA
SAN**
V1
V2
S*
DET
D1
C*
CP
D2
E1
E2
W1
CP
6618 in
DET
16 i
n
4 in
71
5
8 in
1018 in (NOTE 3)
NOTE 1:
THE MAXIMUM DOOR HEIGHT MAY BE
REDUCED BY THE ADDITION OF OPTIONAL
DOOR BRACKETS. MAXIMUM HEIGHTS OF
91", 89" & 87" ARE AVAILABLE.
NOTE 2:
VENTILATION DUCT ADAPTERS ARE
ADJUSTABLE FROM 73-1/2" TO 76".
NOTE 3:
THE DRIVE ASSEMBLY AND GUARD
MAY BE INSTALLED ON EITHER END
OF THE UNIT. INSTALLATION ON THE
UNLOAD END IS STANDARD. IF
INSTALLED ON THE LOAD END,
PLEASE ENSURE ANY SCRAP SINKS
IN THE TABLING ARE AT AN ADEQUATE
DISTANCE TO PROVIDE FOR CLEARANCE
OF THE DRIVE ASSEMBLY.
NOTE 4:
ALL VERTICAL DIMENSIONS MAY
VARY DUE TO THE ADJUSTABLE
FEET.
(NOTE 4)
(NOTE 4)
(NOTE 4)
66" LEFT-TO-RIGHT
*Applies to steam heated units
** Chemical sanitizing units only
*** Pre-wash cold water thermostat option only
SPECIFICATIONS
66" MACHINE DIMENSIONS
NOTE 4:
ALL DIMENSIONS FROM THE
FLOOR CAN BE INCREASED
1 3/4" USING THE MACHINE'S
ADJUSTABLE FEET.
Summary of Contents for crew series
Page 2: ......
Page 6: ......
Page 81: ...72 07610 003 78 18 N STEAM BOOSTER HEATER SCHEMATICS...
Page 84: ...75 07610 003 78 18 N 208 230 460 VOLT 60 HZ 3 PHASE 44 ELECTRICALLY HEATED SCHEMATICS...
Page 85: ...76 07610 003 78 18 N 208 230 VOLT 60 HZ 1 PHASE 44 ELECTRICALLY HEATED SCHEMATICS...
Page 86: ...77 07610 003 78 18 N 208 230 460 VOLT 60 HZ 3 PHASE 44 STEAM HEATED SCHEMATICS...
Page 87: ...78 07610 003 78 18 N 208 230 VOLT 60 HZ 1 PHASE 44 STEAM HEATED SCHEMATICS...
Page 88: ...79 07610 003 78 18 N 208 230 460 VOLT 60 HZ 3 PHASE 66 ELECTRICALLY HEATED SCHEMATICS...
Page 89: ...80 07610 003 78 18 N 208 230 VOLT 60 HZ 1 PHASE 66 ELECTRICALLY HEATED SCHEMATICS...
Page 90: ...81 07610 003 78 18 N 208 230 460 VOLT 60 HZ 3 PHASE 66 STEAM HEATED SCHEMATICS...
Page 91: ...82 07610 003 78 18 N 208 230 VOLT 60 HZ 1 PHASE 66 STEAM HEATED SCHEMATICS...
Page 92: ...83 07610 003 78 18 N BLOWER DRYER 240V SCHEMATICS...
Page 93: ...84 07610 003 78 18 N BLOWER DRYER 480V SCHEMATICS...