18
07610-003-78-18-N
CURTAIN INSTALLATION INSTRUCTIONS
INSTALLATION
The unit has decals marking the curtain locations inside the machine, starting at the load end and ending at the unload
end. The illustrations below indicate the size of the curtain to be placed on the curtain hooks
provided. If any curtain components are missing, these must be obtained and installed before operation.
DETERMINING CONVEYER DIRECTION:
The dishmachine will be configured for either Left-to-Right or Right-to-Left
operation. Direction is from the load end to the unload end, as shown below.
44" Left-to-Right
44" Right-to-Left
XL S
L
L XL
Load
XL L
L
S XL
Unload
Unload
Load
66" Left-to-Right
XL S
L S
L
L XL
Load
Unload
66" Right-to-Left
XL L
L
S L
S XL
Load
Unload
IMPORTANCE OF PROPER CURTAIN PLACEMENT:
The curtains inside the dishmachine must be installed properly
for the machine to operate correctly. Curtains are used to control air currents inside the unit and assist in maintaining the heat
necessary to keep energy costs down. Note the approximate locations for each type of curtain in the above illustrations.
S = Short, L = Long, and XL = Extra Long.
See the chart below for actual curtain lengths and part numbers. Note the
different part numbers for the curtain and curtain rod for the load end when a side-loader option is present.
Legend
Length
Part #
S
12"
08415-131-73-44
L
19"
08415-002-14-41
XL
24.25"
08415-002-47-37
Curtain Rod
20.50"
05700-003-77-52
Side-Loader
Option
Part #
XL
(Load End Only)
08415-003-84-88
Curtain Rod
(Load End Only)
05700-003-84-57
Pre-wash
Pre-wash
Summary of Contents for crew series
Page 2: ......
Page 6: ......
Page 81: ...72 07610 003 78 18 N STEAM BOOSTER HEATER SCHEMATICS...
Page 84: ...75 07610 003 78 18 N 208 230 460 VOLT 60 HZ 3 PHASE 44 ELECTRICALLY HEATED SCHEMATICS...
Page 85: ...76 07610 003 78 18 N 208 230 VOLT 60 HZ 1 PHASE 44 ELECTRICALLY HEATED SCHEMATICS...
Page 86: ...77 07610 003 78 18 N 208 230 460 VOLT 60 HZ 3 PHASE 44 STEAM HEATED SCHEMATICS...
Page 87: ...78 07610 003 78 18 N 208 230 VOLT 60 HZ 1 PHASE 44 STEAM HEATED SCHEMATICS...
Page 88: ...79 07610 003 78 18 N 208 230 460 VOLT 60 HZ 3 PHASE 66 ELECTRICALLY HEATED SCHEMATICS...
Page 89: ...80 07610 003 78 18 N 208 230 VOLT 60 HZ 1 PHASE 66 ELECTRICALLY HEATED SCHEMATICS...
Page 90: ...81 07610 003 78 18 N 208 230 460 VOLT 60 HZ 3 PHASE 66 STEAM HEATED SCHEMATICS...
Page 91: ...82 07610 003 78 18 N 208 230 VOLT 60 HZ 1 PHASE 66 STEAM HEATED SCHEMATICS...
Page 92: ...83 07610 003 78 18 N BLOWER DRYER 240V SCHEMATICS...
Page 93: ...84 07610 003 78 18 N BLOWER DRYER 480V SCHEMATICS...