Delta 1200 Technical Manual 07610-003-62-15 C
Issued: 10-27-2008 Revised: N/A
SECTION 5: SERVICE PROCEDURES
THERMOSTAT REPLACEMENT (CONTINUED)
24
4. Use the 7/16” combination wrench to loosen and remove
the imperial brass fitting. Once this is complete, you should be
able to completely remove the thermostat.
5. Take the new thermostat and place its probe in the new
imperial brass fitting provided in your kit. Use the 7/16” combi-
nation wrench to tighten it down after getting the fitting hand-
tight in the tank.
6. Reconnect the wires per the machine schematic on the
back of the door.
7. Place the drain stopper back in the wash tank. Restore
power and water to the unit. Then allow the unit to operate nor-
mally.
8. Verify that the thermostat operates the heater contactor.
Once you have determined the heater contactor is working,
adjust the wash tank thermostat to ensure that the tempera-
ture is maintained in accordance with the specifications on the
machine data plate.
9. Replace the heater cover.
10. Replace the front door.
AFTER MAINTENANCE ACTIONS
None
SPECIAL NOTES
Work performed on Jackson dishmachines by unau-
thorized or unqualified personnel may void the warranty.
Before beginning this or any other maintenance evolution on a
unit under warranty, you should contact a certified Jackson
technician or Jackson Technical Service. You can find a list of
qualified service agencies in the back of you unit’s installation
manual.
SPECIAL PARTS
Removing the probe and imperial brass fitting.
Removing the thermostat
The completed thermostat replacement
Summary of Contents for Delta 1200
Page 2: ......
Page 6: ...1 SECTION 1 SPECIFICATION INFORMATION ...
Page 9: ...4 SECTION 2 INSTALLATION OPERATION INSTRUCTIONS ...
Page 15: ...10 SECTION 3 PREVENTATIVE MAINTENANCE ...
Page 17: ...12 SECTION 4 TROUBLESHOOTING ...
Page 21: ...16 SECTION 5 SERVICE PROCEDURES ...
Page 33: ...28 SECTION 6 PARTS SECTION ...
Page 48: ...43 SECTION 7 ELECTRICAL SCHEMATICS ...
Page 50: ......