Delta 1200 Technical Manual 07610-003-62-15 C
Issued: 10-27-2008 Revised: N/A
SECTION 1: SPECIFICATION INFORMATION
SPECIFICATIONS
2
Delta 1200
OPERATING CAPACITY (RACKS/HOUR)
GLASSES PER HOUR
1200
OPERATING CYCLE
(SECONDS)
TOTAL CYCLE TIME
120
TANK CAPACITY (GALLONS)
3.0
WASH PUMP CAPACITY
WASH PUMP
55 GPM
TEMPERATURES
WASH---°F (MINIMUM)
130
RINSE---°F (MINIMUM)
75
ELECTRICAL REQUIREMENTS
WASH PUMP MOTOR HORSEPOWER
1/10
NOTE: Typical Electrical Circuit is based upon (1) 125% of the full amperage load of the machine and (2) typical fixed-
trip circuit breaker sizes as listed in the NEC 2002 Edition. Local codes may require more stringent protection than
what is displayed here. Always verify with your electrical service contractor that your circuit protection is adequate
and meets all applicable national and local codes. These numbers are provided in this manual simply for reference
and may change without notice at any given time.
RINSE
TYPICAL
HEATER
TOTAL
ELECTRICAL
VOLTS
PH
HZ
RATINGS
AMPS
CIRCUIT
208 1 60
220V/3KW
15A
15A
230 1 60
220V/3KW
15A
15A
WATER REQUIREMENTS
INLET TEMPERATURE
130°F
GALLONS PER HOUR
10.0
WATER LINE SIZE NPT (Minimum)
1/2”
DRAIN LINE SIZE NPT (Minimum)
1-1/2”
FLOW PRESSURE P.S.I.
20
±
5
MINIMUM CHLORINE REQUIRED (PPM)
50
MINIMUM IODIPHOR REQUIRED (PPM)
12.5
NOTE: Always refer to the machine data plate for specific electrical and water requirements. The material provided on
this page is for reference only and may be subject to change without notice.
Summary of Contents for Delta 1200
Page 2: ......
Page 6: ...1 SECTION 1 SPECIFICATION INFORMATION ...
Page 9: ...4 SECTION 2 INSTALLATION OPERATION INSTRUCTIONS ...
Page 15: ...10 SECTION 3 PREVENTATIVE MAINTENANCE ...
Page 17: ...12 SECTION 4 TROUBLESHOOTING ...
Page 21: ...16 SECTION 5 SERVICE PROCEDURES ...
Page 33: ...28 SECTION 6 PARTS SECTION ...
Page 48: ...43 SECTION 7 ELECTRICAL SCHEMATICS ...
Page 50: ......