background image

Performance/Capacities

P

ot

washer

s

• Water usage — 6.5 gallons per cycle

• 12 cycles per hour

• Fully automatic cycle - 260 seconds

• Incoming water pressure regulator

• Internally mounted electric booster

heater

- Capable of minimum 60°F temper-

ature rise for required 180°F
minimum sanitizing rinse temperature

• One (1) 9 KW  Heating Element in a

9 1/2 gallon rinse tank

• Two (2) Rotating Wash Arms - 

1 upper & 1 lower

• Stationary Rinse Nozzles - 

Top & Bottom

• 40 Gallon Wash Tank

• Electromechanical controls

- Safety door switch
- Temperature control thermostat 

and low water protection

• Construction - 12 & 14 gauge 

stainless steel

• Operational and cleanability features

- High pressure, all stainless steel

wash arms 

- 32” wide x 30” high door opening 
- Double filtration system
- Externally mounted spray down

hose with spray gun nozzle

- Waterproof LED ditigal gauges
- Three wash cycles

• Installation features

- Stainless steel control panel - easily

accessible      

- Adjustable bullet feet
- Detergent/rinse additive signal 

connection fuse box

Standard Features

Operating Capacity

Racks per Hour

12

Operating Cycle (Seconds)

Light

Wash Time 

180

Dwell Time 

20

Rinse Time

60

Total Cycle 

260

Medium

Wash Time 

300

Dwell Time 20

Rinse Time

60

Total Cycle 

380

Heavy

Wash Time 

420

Dwell Time 

20

Rinse Time

60

Total Cycle 

500

Operating Temperatures

Wash — °F (Minimum)

150

Rinse — °F (Minimum)

180

Frame Dimensions (Inches)

Width

36

Depth

51 (53 gas)

Height

84 1/2

Height (door open)

Electric

106

Gas

108 1/2

Wall Clearanse (Minimum)

16

Wall Clearance 

(Control Panel Side)

36 Wall

Clearance (Back)

12

Shipping Weight (Lbs.)

1150

Shipping Size (Inches)

Width

42

Depth

60

Height

90

Electrical Rating
Wash Pump Motor Horsepower

10.0

Full Load Amps

208V

230V

460V

Electric

79.0

72.2

37.1

Steam Injectors

54.0

49.6

25.8

Steam Coils

29.0

27.0

14.5

Gas

54.0

49.6

25.8

Gas Requirements
Gas Connection (NPT)

1/2

Natural Gas (Inches-water column)

Minimum inlet

7.0

Main Manifold

6.0

BTU

48,000

Propane (Inches-water column)

Minimum inlet

11.0

Main Manifold

11.0

BTU

48,000

3” Stainless steel chimney on back of machine

Steam Requirements
Steam connection (NPT)

3/4

Injectors (Lbs per hour)

23

Coils (Lbs per hour)

43

Water Requirements
Inlet Temperature (Minimum)

140°F

Gallons per Hour

78

Gallons per Rack

6.5

Waterline Size IPS (Minimum) (Inches)

1/2

Drainline Size IPS (Minimum) (Inches)

1 1/2

Flow Pressure (PSI)

15-25

Power/Connections

FL-14

 