Performance/Capacities
P
ot
washer
s
• Water usage — 6.5 gallons per cycle
• 12 cycles per hour
• Fully automatic cycle - 260 seconds
• Incoming water pressure regulator
• Internally mounted electric booster
heater
- Capable of minimum 60°F temper-
ature rise for required 180°F
minimum sanitizing rinse temperature
• One (1) 9 KW Heating Element in a
9 1/2 gallon rinse tank
• Two (2) Rotating Wash Arms -
1 upper & 1 lower
• Stationary Rinse Nozzles -
Top & Bottom
• 40 Gallon Wash Tank
• Electromechanical controls
- Safety door switch
- Temperature control thermostat
and low water protection
• Construction - 12 & 14 gauge
stainless steel
• Operational and cleanability features
- High pressure, all stainless steel
wash arms
- 32” wide x 30” high door opening
- Double filtration system
- Externally mounted spray down
hose with spray gun nozzle
- Waterproof LED ditigal gauges
- Three wash cycles
• Installation features
- Stainless steel control panel - easily
accessible
- Adjustable bullet feet
- Detergent/rinse additive signal
connection fuse box
Standard Features
Operating Capacity
Racks per Hour
12
Operating Cycle (Seconds)
Light
Wash Time
180
Dwell Time
20
Rinse Time
60
Total Cycle
260
Medium
Wash Time
300
Dwell Time 20
Rinse Time
60
Total Cycle
380
Heavy
Wash Time
420
Dwell Time
20
Rinse Time
60
Total Cycle
500
Operating Temperatures
Wash — °F (Minimum)
150
Rinse — °F (Minimum)
180
Frame Dimensions (Inches)
Width
36
Depth
51 (53 gas)
Height
84 1/2
Height (door open)
Electric
106
Gas
108 1/2
Wall Clearanse (Minimum)
16
Wall Clearance
(Control Panel Side)
36 Wall
Clearance (Back)
12
Shipping Weight (Lbs.)
1150
Shipping Size (Inches)
Width
42
Depth
60
Height
90
Electrical Rating
Wash Pump Motor Horsepower
10.0
Full Load Amps
208V
230V
460V
Electric
79.0
72.2
37.1
Steam Injectors
54.0
49.6
25.8
Steam Coils
29.0
27.0
14.5
Gas
54.0
49.6
25.8
Gas Requirements
Gas Connection (NPT)
1/2
Natural Gas (Inches-water column)
Minimum inlet
7.0
Main Manifold
6.0
BTU
48,000
Propane (Inches-water column)
Minimum inlet
11.0
Main Manifold
11.0
BTU
48,000
3” Stainless steel chimney on back of machine
Steam Requirements
Steam connection (NPT)
3/4
Injectors (Lbs per hour)
23
Coils (Lbs per hour)
43
Water Requirements
Inlet Temperature (Minimum)
140°F
Gallons per Hour
78
Gallons per Rack
6.5
Waterline Size IPS (Minimum) (Inches)
1/2
Drainline Size IPS (Minimum) (Inches)
1 1/2
Flow Pressure (PSI)
15-25
Power/Connections
FL-14