07610-004-33-05-E
13
SPECIFICATIONS
OPERATING PARAMETERS
Always refer to the machine data plate for specific electrical and water requirements.
The material provided on this page is for reference only and may change without notice.
NOTICE
i
HOT-WATER SANITIZING
Water Temperatures (°F):
RackStar
44
RackStar
66
RackStar
44S
RackStar
66S
RackStar
44ER
RackStar
66ER
Pre-wash Temperature
N/A
110-140
N/A
110-140
N/A
110-140
Minimum Wash Temperature
160
160
160
160
160
160
Incoming Rinse Temperature
180
180
180
180
180
180
Minimum Incoming Water Temperature
12 kW Booster (40º Rise)
140
140
N/A
N/A
N/A
N/A
18 kW Booster (70º Rise)
110
110
N/A
N/A
N/A
N/A
27 kW Booster (ER Only)
N/A
N/A
N/A
N/A
110
110
No Booster
180
180
180
(from Steam
Booster)
180
(from Steam
Booster)
N/A
N/A
Minimum Incoming Cold Water
Temperature (ER Units Only)
N/A
N/A
N/A
N/A
55
55
CHEMICAL SANITIZING
Water Temperatures (°F):
RackStar
44
RackStar
66
RackStar
44S
RackStar
66S
RackStar
44ER
RackStar
66ER
Pre-wash Temperature
N/A
110-140
N/A
N/A
N/A
N/A
Minimum Wash Temperature
120
120
N/A
N/A
N/A
N/A
Incoming Rinse Temperature
120
120
N/A
N/A
N/A
N/A
Minimum Incoming Water
Temperature
110
110
N/A
N/A
N/A
N/A
Other Water Requirements:
RackStar
44
RackStar
66
RackStar
44S
RackStar
66S
RackStar
44ER
RackStar
66ER
Water Flow Pressure (PSI)
15
15
15
15
15
15
Flow Rate Minimum (GPM)
1.3
1.3
1.3
1.3
1.3
1.3
Water Line Size (NPT)
1/2"
1/2"
1/2"
1/2"
1/2"
1/2"
Drain Line Size (NPT)
1 1/2"
1 1/2"
1 1/2"
1 1/2"
1 1/2"
1 1/2"
Steam Requirements:
RackStar
44
RackStar
66
RackStar
44S
RackStar
66S
RackStar
44ER
RackStar
66ER
Steam Line for Wash Tank (NPT)
N/A
N/A
3/4"
3/4"
N/A
N/A
Steam Flow Pressure (PSI)
N/A
N/A
10-30
10-30
N/A
N/A
Consumption @ 15 PSI (lbs/hr)
N/A
N/A
60
60
N/A
N/A