07610-002-23-32-AD
18
To delime the machine, follow the steps below. The tank capacities of the machine
can be found on the Operating Parameters section of this manual.
1. Remove rinse arms and place in sink with deliming solution.
2. Disconnect or turn off chemical feeder pumps.
3.
Add deliming solution per chemical supplier’s instructions.
4.
Close the door and turn the machine on in "MANUAL" mode.
5. Run the machine for the length of time recommended by the chemical supplier.
6. Flip the mode switch to "AUTO" to shut the unit off.
7.
Open the door and step away for five minutes.
8. Inspect the inside of the machine. If the machine is not delimed, run again.
9.
When clean, drain and re-fill the machine.
10. Run two cycles in "AUTO" to remove residual deliming solution.
11.
Drain and re-fill the machine.
12. Flush rinse arms with water and replace.
CAUTION!
This equipment is not recommended for use with deionized water or other
aggressive fluids. Using deionized water or other aggressive fluids will result in corrosion and
failure of components and will void the warranty.
DELIMING
Mode Switch
Power Switch
DELIMING
OPERATION
!
CAUTION
Summary of Contents for TEMPSTAR HH S
Page 35: ...07610 002 23 32 AD 26 1 5 4 2 3 6 7 10 8 9 HOOD PARTS ...
Page 61: ...07610 002 23 32 AD 52 VER SYSTEM PARTS 18 24 23 12 11 16 17 14 21 22 20 19 27 28 29 ...
Page 67: ...07610 002 23 32 AD 58 SCHEMATICS HH E VER 208 230 V NEW RINSE TANK ...
Page 68: ...59 07610 002 23 32 AD SCHEMATICS HH E VER 460 V NEW RINSE TANK ...
Page 69: ...07610 002 23 32 AD 60 SCHEMATICS HH E VER 208 230 V OLD RINSE TANK ...
Page 70: ...61 07610 002 23 32 AD SCHEMATICS HH E VER 460 V OLD RINSE TANK ...
Page 71: ...07610 002 23 32 AD 62 SCHEMATICS NB 208 230 V ...
Page 72: ...63 07610 002 23 32 AD SCHEMATICS NB 460 V ...
Page 73: ...07610 002 23 32 AD 64 SCHEMATICS HH S 208 230 V ...
Page 74: ...65 07610 002 23 32 AD SCHEMATICS SDI OPTIONS ...