17

Alarm and volume

The alarm is activated when there is smoke in the detector . The alarm signal is 

approximately 85dB/3m . The alarm signal is active as long as there is smoke in  

the detector . When there is no longer smoke in the detector, the smoke alarm  

will revert to stand-by / normal operation automatically . 

Alarm signals

Acoustic signal

One short beep app . every minute indicates that the battery is weak and must  

be replaced .

Two short beeps indicate malfunction due to background light or outer 

interruptions of the smoke chamber .

Three short beeps indicate technical malfunctions .

Four short beeps indicate that the smoke alarm is dirty and must be cleaned .

A continuous sound indicates that there is smoke in the detector .

Visual signal

One flash every eighth seconds indicates normal operation .

Two flashes every eighth seconds indicate reduced sensitivity (pause function) .

A continuous flash indicates smoke detection .

How to stop the alarm

One short beep app. every minute:

Replace the battery . (See further under "Replacement of battery”) .

Two short beeps:

Remove the background light or outer interruptions which causes the  

disturbance of the smoke alarms operation .

Three short beeps:

The smoke alarm needs to be tested .

Note: Modifying or tampering with the internal components of the smoke  

alarm may cause malfunction and will invalidate the warranty .

Four short beeps: 

Clean the smoke alarm . (See further under "Maintenance") .

Continuous signals (both visual and acoustic):

Alarm for smoke detection / fire .

(The alarm will sound as long as there is smoke in the detector . 

The alarm can be stopped by pressing the red test button .)

Mounting

The smoke alarm should be fitted using the enclosed  

mounting bracket, which is to be mounted in the 

ceiling with one screw only (screw and plug for 5 mm 

drill enclosed – please use a special plug for plaster 

ceilings) .

When the bracket is fixed, the smoke alarm is attached with a click . It is now firm 

but can be turned for adjustment around the point to which it is attached .

Replacement of battery

The mounting plate makes it easy to pull down the smoke alarm for cleaning and 

for replacement of the battery . As an extra safety precaution, the smoke alarm 

cannot be mounted without a battery . The smoke alarm requires one 9 VDC 

battery, (included – mounted in the battery-compartment) .

Please note: The smoke alarm normally operates up to 10 days from the first 

indication of low battery .

Please note: At first time installation simply remove the plastic strip between the 

terminals and the contact before mounting the smoke alarm .

Note: For optimal detection the smoke alarm should be installed in a suitable 

location as described above .

After mounting and after every battery change, test the smoke alarm by pressing 

the red test button until a penetrating, clear signal is heard . Make sure that 

the red test button flashes every eighth second . When the alarm is set-off, a 

penetrating, rapidly pulsating signal is given out (min . 85dB/3m) . The alarm can 

be stopped by pressing the red test button .

Maintenance

The following guidelines will help you care for the 

JACOB JENSEN

TM

 Smoke Alarm 

so you can enjoy using it for many years .

1 . Keep the smoke alarm dry at all times . If it becomes wet, wipe it dry 

immediately and remove the batteries . Liquids can contain minerals that might 

corrode the electric circuits .

2 . Use and store the smoke alarm only under normal temperature . Temperature 

extremes can shorten the life of electronic components, damage the battery 

and distort or melt plastic parts .

3 . Handle the smoke alarm gently and with care . If it is dropped, circuit boards 

can be damaged, resulting in malfunction .

4 . Keep the smoke alarm free from dust and dirt to avoid the premature wear of 

parts .

5 . Clean the smoke alarm by wiping with a soft cloth . Do not use aggressive 

chemicals, cleaning solvents or strong detergents .

6 . Use only fresh batteries of the required size and type . We recommend Alkaline/ 

Top Grade batteries only . Always remove old or weak batteries as they might 

leak chemicals that will destroy the smoke alarm .

7 . Modifying or tampering with the internal components of the smoke alarm may 

cause malfunction and will invalidate the warranty .

Summary of Contents for JBXS03

Page 1: ...Smoke Alarm Optical Vejledning Bruksanvisning Brukerveiledning Gebruikshandleiding User manual Bedienungsanleitung Manuel d utilisation Istruzioni per l uso Instrukcja obs ugi...

Page 2: ...y response delay response time and performance under fire condition to relevant clauses Pass Operational reliability Pass Tolerance to supply voltage Pass Durability of operational reliability and res...

Page 3: ...r hj rne R gdetektorer kan godt placeres under skr t loft hvis f lgende overholdes hvis lofth jden er under 3 m skal r galarmen placeres 3 20 cm under loft hvis lofth jden er mellem 3 og 6 m skal den...

Page 4: ...lleret R galarmen bruger 1 stk 9V batteri inkluderet monteret i batteriboksen Obs F rste gang r galarmen skal monteres fjernes blot plastikstrippen mellem pol og kontakt Bem rk For optimal detektion s...

Page 5: ...des i overensstemmelse med lovgivningen og ikke un digt belaster milj et Alle kommuner har etableret indsamlingsordninger hvor kasseret elektrisk og elektronisk udstyr samt b rbare batterier gratis ka...

Page 6: ...er f lsomhed responsforsinkelse responstid og ydeevne under brand iht relevante bestemmelser godkendt Krav til driftssikkerhed godkendt Krav til tolerance iht forsyningsstr m godkendt Krav til driftss...

Page 7: ...je v ning Det r viktigt att kontrollera att larmsignalen h rs fr n varje sovrum Om n dv ndigt placera ven brandvarnare i sovrummet Brandvarnaren b r helst placeras mitt i rummet alltid minst 0 5 meter...

Page 8: ...ner brandvarnaren f r byte av batteri eller reng rning En extra s kerhetsfunktion g r att brandvarnaren ej kan monteras utan batteri Brandvarnaren anv nder 1 styck alkaliskt 9V batteri som medf ljer i...

Page 9: ...ordna en utv ndig stege eller lina 2 Best m en plats utanf r huset d r familjen samlas vid larm 3 H ll helst sovrumsd rren st ngd under natten En d rr kan h lla branden borta s pass l nge att man hin...

Page 10: ...seres under skr tt tak hvis f lgende overholdes dersom takh yden er under 3 m skal r ykvarlseren plasseres 3 20 cm under taket hvis takh yden er mellom 3 og 6 m skal den plasseres 3 20 cm under taket...

Page 11: ...Utskiftning av batteri Beslaget gj r det lett og enkelt trekke alarmen av for skifte av batteri og rengj ring En ekstra sikkerhetsfunksjon gj r at r ykvarsleren ikke kan monteres uten at et batteri e...

Page 12: ...er til rommet hvor det brenner hvis du m forlate rommet Enhver lukket d r mellom det brennende rom og vrige kan hindre ildens fortplantning 4 Ta imot veiled brannvesenet n r de kommer tilstede Ta even...

Page 13: ...oonlagen dient er op elke etage minimaal n rookmelder geplaatst te worden Het is belangrijk om te testen of het alarm in elke kamer goed te horen is Plaats indien noodzakelijk een extra alarm in de sl...

Page 14: ...de rode testknop te drukken Montage De rookmelder dient gemonteerd te worden met het bijgesloten bevestigings busje met behulp van n enkele schroef schroef en plug voor 5 mm boor bijgesloten gebruik...

Page 15: ...niet bestrijd Is er blusmateriaal beschikbaar in uw huis Zelfs een kleine rookontwikkeling kan fataal zijn In geval van brand Beschermen waarschuwen doven 1 Waarschuw iedereen die mogelijk in gevaar...

Page 16: ...ne smoke alarm on each floor It is important to test that the smoke alarm can be easily heard from every bedroom If necessary a smoke alarm should be installed in the bedroom The smoke alarm should be...

Page 17: ...ch it is attached Replacement of battery The mounting plate makes it easy to pull down the smoke alarm for cleaning and for replacement of the battery As an extra safety precaution the smoke alarm can...

Page 18: ...for the fire brigade by the telephone 3 If possible try to put out the fire with your fire fighting equipment Isolate the fire by closing doors and windows to the room on fire Any closed door to the...

Page 19: ...gen In einem Haus mit mehreren Wohnetagen sollte mindestens ein Smoke Alarm pro Etage eingesetzt werden Sie sollten unbedingt testen ob der Rauchmelder bei Alarm auch jederzeit von allen Schlafzimmern...

Page 20: ...e Eingriffe bez glich der technischen Komponenten des Smoke Alarms k nnen Fehlfunktionen ausl sen und f hren zum Erl schen des Garantieanspruchs Vier kurze Piept ne Reinigen Sie den Smoke Alarm Siehe...

Page 21: ...stellungsfehlern ist Dies gilt nur f r den normalen Gebrauch und Pflege Ausgenommen von der Garantie sind Fehler durch Fremdeingriffe oder nicht zul ssige Modifikationen Ihre gesetzlichen Rechte als V...

Page 22: ...ologische Bedenken und Entsorgung Elektrische und elektronische Ger te und die beiliegenden Batterien enthalten Materialien Komponenten und Substanzen die Ihrer Umwelt und Gesundheit schaden k nnen we...

Page 23: ...tage Il est important de tester si l alarme du d tecteur est bien audible de chaque pi ce Si n cessaire un d tecteur devrait tre install dans la chambre coucher Le d tecteur devra alors tre plac au mi...

Page 24: ...fix le d tecteur s y attache avec un click Il est maintenant ferme mais il peut tre tourn pour tre ajust autour du point auquel il est attach Remplacement de la pile La plaque install e facilite le d...

Page 25: ...tre maison Rappelez vous que m me une petite quantit de fum e peut tre fatale Si un incendie se d clare Sauver Alerter Eteindre 1 Alertez toute personne qui pourrait tre en danger 2 Avertissez les pom...

Page 26: ...ima consigliata tra un dispositivo e l altro di 10 metri In un abitazione disposta su pi piani necessario posizionare un rilevatore su ogni piano E importante verificare che il segnale d allarme possa...

Page 27: ...do una sola vite vite e tassello per trapano da 5mm inclusi per soffitti in cartongesso si raccomanda l uso di tasselli appositi Dopo aver montato la staffa ed aver fissato il rilevatore assicurarsi c...

Page 28: ...mo pu essere fatale In caso di incendio Mettere in sicurezza Avvisare Spegnere 1 Avvisare tutti coloro che potrebbero essere in pericolo 2 Chiamare i vigili del fuoco Tenere memorizzato il loro numero...

Page 29: ...rzeciwpo arowy b dzie atwo us ysze z ka dej sypialni Je eli to konieczne czujnik dymu powinien by zainstalowany w sypialni Alarm przeciwpo arowy powinien by umieszczony na rodku sufitu co najmniej 0 5...

Page 30: ...yta monta owa pozwala na atwe ci gni cie alarmu przeciwpo arowego w celu wyczyszczenia i wymiany baterii W ramach dodatkowego zabezpieczenia alarm przeciwpo arowy nie mo e zosta zamontowany bez bater...

Page 31: ...stwie 2 Powiadom stra po arn Zawsze nale y mie numer do stra y po arnej wpisany do telefonu 3 Je li to mo liwe postaraj si ugasi ogie za pomoc sprz tu ga niczego Wyizoluj ogie poprzez zamkni cie drzwi...

Page 32: ...Product by Bell Xpress A S Denmark www bellxpress dk www jacobjensen com Generation to generation...

Reviews: