TROUBLESHOOTING 5
GB-19
5.2
CONTROLLER LAMPS _____________________________________________________
The controller is a solid state device that monitors and
controls electrical functions. The controller receives input
signals from various switches and sensors throughout the
machine and transmits output signals to operate relays,
solenoids and warning lights. It controls and resets timers
and contains built in logic to control certain machine
functions.
Each input and output signal is displayed through lamps
located on top of the controller. A closed input switch
indicates an active circuit and will turn an input lamp on. An
open switch an inactive circuit and will turn a lamp off.
Outputs are active when their lights are on.
It is important to note that in some cases a lamp or group of
lamps must be on or off for a condition to be true. For
example, to start the mower the Mow Switch must be off
(lamp 8 off) while the Neutral Start Switch (lamp 12), Brake
Switch (lamp 6) and Fuel Valve Hold Coil (lamp 27) must be
on.
NOTICE
For factory assistance with troubleshooting controller
problems, please note the controller hardware revision
and software version located on the lower right corner of
the controller.
[
SEE
Parts & Maintenance Manual]
Controllers with equal or greater revision levels will be
backward compatible.
Controller Functions by Lamp Number
Lamp On - Circuit is active
Lamp Off - Circuit is inactive
INPUTS
OUTPUTS
Lamp
Circuit
Lamp
Circuit
1,2,3,4
Program Select (1, 3 and 4 are not used)
19
Hydraulic Filter Light
5
Brake Switch
20
Hydraulic Oil Level Light
6
Seat Switch
21
Not Used
7
Traction Control Switch
22
Glowplug Light
8
Mow Switch
23
Lower Solenoid
9
Joystick - Lower
24
Raise Solenoid
10
Joystick - Raise
25
Glowplug Relay
11
Hydraulic Oil Level Switch
26
Start Relay
12
Neutral Switch
27
Fuel Solenoid - Hold
13
Not Used
28
Not Used
14
Keyswitch - Glowplug
29
Audible Alarm
15
Keyswitch - Start
30
Mow Solenoid
16
Joystick Active
31
Fuel Solenoid - Pull
17
Hydraulic Filter Switch
32
Power-Ignition
18
Engine Oil Pressure Switch
33
Power-Lights
L
a
mp
1
2
3
4
5
6
7
8
9
10
11
12
1
3
14
15
16
17
1
8
19
20
21
22
2
3
24
25
26
27
2
8
29
3
0
3
1
3
2
33
INPUTS
OUTPUTS