CONTROLS 4
13
4.3
LCD DISPLAY _____________________________________________________________
The LCD displays current functional values for the
operation of the Eclipse mower and sounds one of three
types of audible alerts. The LCD operates in one of two
modes, Operator Mode (Default) and Superintendent
Mode. Use of Superintendent mode requires a four digit
pin number.
Press either of the orange buttons
(K or L)
to change
screen display or change values. Push the right orange
button
(K)
to go forward in the display list or increase
setting value, and push the left orange button
(L)
to go
back in the display list or decrease setting value. The
black button
(J)
is used to select, reset or change values.
Figure 4B
Audible Alerts
indicate one of three conditions detected
by the LCD Display and a corresponding message would
show on the display. A solid tone indicates low system
voltage. A fast beeping (2 per second) alert indicates an
over voltage condition. A slow beeping (1 every 3
seconds) alert indicates mower is in backlap mode.
Alert Displays:
In addition to the standard displays for
each mode, there are four displays that are used to alert
the operator/mechanic of a problem the needs to be
corrected.
Figure 4C
Low Voltage
display is shown when system voltage
drops below 42 Volts DC for 30 seconds and an solid
tone alarm will sound. Press the black button
(J)
to
silence the alarm. Return mower to storage area or
install a fully charged battery pack. Reel motor will
not operate with low voltage on the display.
Overvoltage/Check Voltage
display is shown when
system voltage is above 60 Volts DC and a fast (2
per second) beeping alarm will sound. If not
corrected, controller will shut down after 60 seconds.
Check generator output before restarting system.
[See Section 10.3]
Reel Motor Fault
display is shown when a reel
motor short circuit is detected or the reel motor
current draw exceeds 30 Amps for one second. Reel
motor will not operate until the problem is resolved.
Return mower to maintenance area for repair.
Traction Motor Fault
display is shown when a
traction motor short circuit is detected or the traction
motor current draw exceeds 30 Amps for one
second. Traction motor will not operate until the
problem is resolved. Return mower to maintenance
area for repair.
Operator Mode
is used by the operator for system
voltage information, travel speed, FOC setting and reel
speed. Press the orange buttons
(K and L)
on the front
handle cover to toggle between the different displays.
Operator Mode is view only, no system settings can be
changed.
If reel switch is placed into backlap position while in
operator mode, the reel motor will stop immediately and
screen will display “Turn Backlap Switch Off”. Backlap is
only available in Superintendant Mode.
Figure 4D
G
J
K
L
REEL
MOTOR FAULT
LOW BATTERY
42.0 VDC
OVERVOLTAGE
CHECK VOLTAGE
TRACTION
MOTOR FAULT
Alert Displays
WARNING
Turn reel switch off, release bail, turn key to off
position and disconnect battery connector before
checking for obstructions in reel.
!
JACOBSEN
VERSION X.XX
TRAVEL SPEED
3.4 MPH
SYSTEM VOLTS
48.0 VDC
REEL SPEED
2200 RPM
TURN BACKLAP
SWITCH OFF
FOC = 0.146
Standard start up
screen
Displays system
voltage.
Displays travel
speed of mower.
Displays reel rotation
speed.
Displays fixed FOC
setting.
Display if Reel Switch
is placed in backlap
position.