MAINTENANCE 4
GB-19
4.8
BATTERY ________________________________________________________________
Make absolutely certain the ignition switch is “Off” and the
key has been removed before servicing the battery.
Tighten cables securely to battery terminals and apply a
light coat of silicone dielectric grease to terminals and cable
ends to prevent corrosion. Keep vent caps and terminal
covers in place
Check the electrolyte level every 100 hours. Keep the cable
ends, battery and battery posts clean.
Verify battery polarity before connecting or disconnecting
the battery cables.
1.
When installing the battery, always assemble the RED,
positive (+) battery cable first and the ground, BLACK,
negative (-) cable last.
2.
When removing the battery, always remove the ground,
BLACK, negative (-) cable first and the RED, positive
(+) cable last.
3.
Make sure battery is properly installed and secured to
the battery tray.
4.9
JUMP STARTING __________________________________________________________
Before attempting to “jump start” the tractor, check the
condition of the discharged battery. Section 4.8
When connecting jumper cables:
1.
Stop the engine on the vehicle with a good battery.
2.
Connect RED jumper cable to the positive (+) terminal
on the good battery and to the positive (+) terminal on
the “discharged” battery.
3.
Connect the BLACK jumper cable from the negative
(-) terminal on the good battery to the frame of the
tractor with the discharged battery.
After cables have been connected, start the engine on the
vehicle with the good battery then start the tractor.
4.10 CHARGING BATTERY _____________________________________________________
1.
Refer to Section 4.8. Read the Battery and Charger’s
manual for specific instructions.
2.
Whenever possible, remove the battery from the tractor
before charging. If battery is not sealed, check that the
electrolyte covers the plates in all the cells.
3.
Make sure the charger is “Off”. Then connect the
charger to the battery terminals as specified in the
charger’s manual.
4.
Always turn the charger “Off” before disconnecting
charger from the battery terminals.
CAUTION
Always use insulated tools, wear protective glasses or
goggles and protective clothing when working with
batteries. You must read and obey all battery
manufacturer’s instructions.
!
WARNING
Batteries generate explosive hydrogen gas. To reduce
the chance of an explosion, avoid creating sparks near
battery. Always connect the negative jumper cable to the
frame of the tractor with the discharged battery, away
from the battery.
!
WARNING
Charge battery in a well ventilated area. Batteries
generate explosive gases. To prevent an explosion, keep
any device that may create sparks or flames away from
the battery.
To prevent injury, stand away from battery when the
charger is turned on. A damaged battery could explode.
!