5-110
5
M
A
INTE
NAN
CE
ARBUS 1000
Mechanical agitator
• At any sign of the drain (B) leak, replace
the mechanical seal. Contact your nearest
Jacto dealer.
• Replace the grease every 500 working
hours according to specifications in the
lubrication table.
Whell hub
• Check the pump oil level (A) daily and fill
it if necessary.
Chemical pump
NOTE:
In case of need for a more de-
tailed maintenance (replace-ment
of piston cups, bearings, etc.),
contact the nearest JACTO dealer.
A
A
ATTENTION!
Place the sprayer on a firm and
level ground and scotch its wheels
before lubricating the wheel hub.