5-66
5
M
A
INTE
NAN
CE
ARBUS 270
• The filter cleaning intervals depend on
the quality of the water employed and the
type of chemical used for that purpose.
• Clean the filters as necessary or every time
you supply the sprayer with chemical.
The nozzle holder are mounted according to
the figures: valve (A), ilter element (B), ring (C)
e filter cap (D).
Main filter
Pressure regulator
• Disassemble the pressure regulator every
100 working hours.
• Check for wear on the valve seat (E) and
patches (F). Replace the parts if necessary.
D
B
C
A
E
F