CORRECTION
CAUSE
PROBLEM
Worn or dried out piston cup.
Leakage through the cylinder
upper part (1).
Lubricate or replace
the piston cup.
After pumping and pressurizing
the chamber, the lever drops
Cylinder valve (2) not sealing
properly due to wear or impu-
rities.
Clean or replace
the valve.
15- TROUBLESHOOTING
- Pour about 0,5 gallons of clean water into the tank.
- While operating the pumping lever, look inside the tank to investigate the problem.
- Refer to the table and diagram below.
After pumping and pressurizing
the chamber, the lever rises
slowly when released.
Clean or replace
the valve.
Chamber valve (3) not sea-
ling properly due to wear or
impurities.
Chamber
1
7
6
Cylinder (2)
5
4
3
14- CYLINDER MAINTENANCE
DISASSEMBLING
- Remove the chamber from the cylinder.
- Remove the nuts (1) from the cylinder.
- Remove the cylinder (2).
- Loosen the bolts (3), remove the spring (4), ball seat
(5) and ball (6).
- Clean or replace the parts that show wear.
ASSEMBLING
- Install the ball, ball seat, spring and bolts (3) on the
cylinder base (7).
- Next, position the base (7) on the cylinder (2) and
secure it with the bolts (3).
- Install the complete assembly on the sprayer and secure
it with the nuts (1).