03/23/05                          J600CHT Assembly – DRAFT              Prepared for Jacto  
                                                                                                        Service Seminar 3/2005 
                                                                                                        DRAFT COPY 

 

Stationary Duct Assembly 

 
 
 

1)

 

Install the stationary duct on the top of the fan housing.  It is recommended the 4 

bolts that attach the stationary duct to the frame be installed first to help align the 
other 12 holes around the flange of the duct.  Please note two of the 4 bolts need to be 
installed from the inside of the duct opening to the frame.  It may be difficult to align 
the remaining holes and in some instances loosening the bolts that hold the fan 
housing to the frame may be necessary.  The duct flange bolts can usually be threaded 
into the holes to help with alignment.  You will notice one bolt is inserted into the 
flange from the factory due to the fact the horizontal cylinder is already installed and 
does not allow this bolt to be removed.  The picture below shows the proper 
positioning of the stationary duct.    

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

Summary of Contents for J600

Page 1: ...cover for disconnect and accessory box with the required fasteners to assembly the sprayer Accessory Box The above picture shows the parts that you will find inside the accessory box The hardware wil...

Page 2: ...op of the tank towards the center as shown below Install the blue return hoses and clamps to the control valve Note the hose coming from the centrifugal pump connects to bottom outlet of control valve...

Page 3: ...bolts need to be installed from the inside of the duct opening to the frame It may be difficult to align the remaining holes and in some instances loosening the bolts that hold the fan housing to the...

Page 4: ...rear of the sprayer Align the two holes in the duct with the bushing holes in the stationary duct and insert the bushings supplied into the pivot holes The bushing must seat properly into the recess i...

Page 5: ...the two brackets with the pins on the cylinder inserted into the holes on the brackets Pay close attention to the positioning of the two brackets as shown below and install the three mounting bolts Be...

Page 6: ...o supply hoses through the hose retainer clips on the duct and tighten These two hoses should then be routed through the hose loops on the back of the duct and then threaded into the orange sheath up...

Page 7: ...nd Clean Water Tank 1 Install the PTO shaft by sliding the implement end over the drive shaft and aligning the key way with the key Install the retaining bolt and tighten 2 Install the clean water tan...

Page 8: ...r length To determine the proper length required for the tractor being used the operator must lift the sprayer until the shortest distance between the sprayer s drive shaft and the tractor s PTO drive...

Reviews:

Related manuals for J600