Jacto SP 312 / SP 416
Jacto SP 312 / SP 416
9
8
Spray nozzle
Calibration
Lance
Cover
Filter
Nozzle
Nozzle cap
Calibration bottle
Band width
Band width (feet)
1.6
2.2
3.2
3.9
4.9
Distance to walk (feet)
164
117.1
82
68.2
54.7
Attach the calibrator bottle to the lance as shown:
Hold the lance at the working height and
spray to measure the application band
width. Based on the band width, calculate
the total walking distance required to spray
the desired area 269.1 ft
2
.
A - Remove the cap, nozzle and filter.
B - Mount the calibrator cover to the
lance.
C - Reinstall the filter, nozzle and cap.
D - Screw the calibrator onto the
cover.
Hold the lance at the normal working
height and spray into the bottle while
walking the distance required to spray
an area corresponding to 269.1 ft
2
.
Place the bottle on a level surface
and observe the liquid level visible
through the side of the bottle. Match
the liquid level to the correspond-
ing scale on the calibrator bottle.
Empty the bottle and repeat this
operation to determine the aver-
age of two or more readings.
> Calibration of manual backpack sprayer
USING CALIBRATOR BOTTLE (optional)
NOZZLE
TYPE
IDENTIFICATION
PRESSURE
(psi)
FLOW RATE
(gallons/minute)
FLAT FAN
1197535 - JEF 110015
GREEN
45
0.16
1197536 - 11002
YELLOW
45
0.21
1197538 - JEF 11003
BLUE
45
0.33
CONE
717942 - JD 10A
45
0.08
217174 - JD 12P
45
0.16
CONE
1197565 - JHC 02
YELLOW
45
0.22
1198892 - JHC 04
RED
45
0.44
1198893 - JHC 05
BROWN
45
0.54
DEFLECTOR
1197486 - JDF 04
RED
15
0.25
1197487 - JDF 05
BROWN
15
0.31
1197488 - JDF 06
GRAY
15
0.41
ADJUSTABLE
CONE
323725 - YELLOW
45
0.08
015024 - RED
45
0.17
325787 -BLUE
45
0.18
* ATTENTION:
This sprayers is supplied with the Blue adjustable cone nozzle fitted
in the lance. Other nozzles mentioned in this manual are optional and purchased
separately.