Export J-380 Models (50Hz)
230V/35A*
230V/40A**
Voltage:
230 VAC
230 VAC
Number of Wires
3
3
Frequency:
50Hz
50Hz
Current Draw:
26A
32A
Circuit Breaker:
35A
40A
Important Information:
*
In 35A configuration, the heater
will not operate
while any two jets
pumps are running in high speed.
Note: jet pumps 2&3 run only in
high speed.
This is the factory setting.
**
In 40A configuration, the heater
will operate
while any two jets
pumps are running in high speed.
Note: jet pumps 2&3 run only in
high speed.
All export models can be adapted to use higher amperage circuits when
available. Please contact your dealer for details. The electrical supply for
this product must comply with local electrical regulations.
Export J-350/J-360/J-370 Models (50Hz)
230V/20A*
230V/30A**
230V/40A***
Voltage:
230 VAC
230 VAC
230 VAC
Number of Wires
3
3
3
Frequency:
50Hz
50Hz
50Hz
Current Draw:
15A
23A
29A
Circuit Breaker:
20A
30A
40A
Important Information:
*
In 20A configuration, the heater
will not operate
while either jets
pump is running in high speed.
Note: jets pump 2 runs only in high
speed.
This is the factory setting.
**
In 30A configuration, the heater
will not operate
when both jets
pumps are running in high speed.
Note jets pump 2 runs only in
high speed.
***
In 40A configuration, the heater
will operate
while both jets pumps
are running in high speed.
All export models can be adapted to use higher amperage circuits when
available. Please contact your dealer for details. The electrical supply for
this product must comply with local electrical regulations.
Page 8