background image

BUILDER BATH SERIES

INSTALLATION/OPERATING INSTRUCTIONS

WHIRLPOOL 

BATH

R

SERIE DE TINAS  BUILDER

MANUAL DE INSTALACIÓN Y OPERACIÓN

Summary of Contents for ALARIS

Page 1: ...BUILDER BATH SERIES INSTALLATION OPERATING INSTRUCTIONS WHIRLPOOL BATH R SERIE DE TINAS BUILDER MANUAL DE INSTALACI N Y OPERACI N...

Page 2: ...iods can be injurious to health To prevent discoloration of the acrylic finish do not fill the bath with water in excess of 140 F IMPORTANT SAFETY INSTRUCTIONS WARNING When using this unit basic preca...

Page 3: ...on ____________________________________________________________________________ 17 20 Funcionamiento Rapid Heat Operation Electrical Connections ______________________________________________ 20 21 Ra...

Page 4: ...perfecto en el terminado no la instale La garant a no cubre da os o desperfectos reclamados despu s de la instalaci n La responsabilidad de Jacuzzi Whirlpool Bath por da os de embarque termina al entr...

Page 5: ...See Page 10 Vea Pagina 10 Yes S LUXURA 5 60 1524 mm L 32 813 mm W 20 1 4 514 mm H 659 lb 300 kg 50 lb sq ft 244 kg sq m 44 U S gal 167 litros 92 lb 42 kg 16 1 4 387 mm A 9 1 4 210 mm B Optional U Fram...

Page 6: ...9 kg Optioal U Frame Template Provided Plantilla Poveida 18 1 2 470 mm A 9 229 mm B Yes SIGNA 60 1524 mm L 42 1067 mm W 22 559 mm H 883 lb 401 kg 51 lb sq ft 249 kg sq m 42 U S gal 159 litros 108 lb 4...

Page 7: ...14 1 2 368 mm A 9 3 8 238 mm B Optional U Frame Opcional marco en U Included U Frame Opcional marco en U 64 x 40 Yes S Yes S TORINO 6 72 1829 mm L 48 1219 mm W 22 1 4 565 mm H 1232 lb 559 kg 51 lb sq...

Page 8: ...TERAL END VIEW VISTA DE FRENTE RIVA 5 RIVA 6 NIVEO 5 NIVEO 6 SIDE VIEW VISTA LATERAL W H 2 25 4 mm L END VIEW VISTA DE FRENTE DRAIN OVERFLOW DESAG E REBOSADERO A B MODEL MODELO PRODUCT WEIGHT PESO OPE...

Page 9: ...EGRADO 55 1397 mm L 55 1397 mm L 20 1 2 521 mm H 1050 lb 477 kg 52 lb sq ft 254 kg sq m 55 U S gal 208 litros 120 lb 54 kg 18 457 mm A 12 1 8 308 mm B Integral Integrado NA No CORNER BATHS TINAS DE ES...

Page 10: ...ano derecha como mostrado solamente ROUGHING IN REFERENCE DIAGRAMAS EN PLANTA DE INSTALACIONES Note Unless otherwise specified units are produced with left or right hand versions Nota Si no se ha espe...

Page 11: ...y pump location Es izquierda o derecha seg n la ubicaci n de la bomba 11 7 8 MAJORA 6 WITH INTEGRAL SKIRT MAJORA 6 CON FALD N INTEGRADO 42 72 12 x 4 21 2 10 1 2 Note Unless otherwise specified units a...

Page 12: ...2 2 24 24 x 4 VANTAGE 60 32 16 2 12 x 4 9 3 8 TORINO 2 1 2 66 21 42 13 1 2 15 x 5 60 32 16 2 12 x 4 9 3 8 VANTAGE WITH INTEGRAL SKIRT VANTAGE CON FALD N INTEGRADO RECTANGULAR BATHS CUTOUT DIAGRAMA EN...

Page 13: ...72 21 2 42 2 14 x 4 11 1 2 NIVEO 6 CAPELLA Capella left and right hand determined by pump location Es izquierda o derecha seg n la ubicaci n de la bomba 27 46 5 8 27 60 43 1 8 33 1 2 6 60 34 15 16 14...

Page 14: ...location Es izquierda o derecha seg n la ubicaci n de la bomba 2 x 4 Stud TARA 27 1 4 35 44 60 60 46 27 1 4 35 14 x 4 ROUGHING IN REFERENCE DIAGRAMAS EN PLANTA DE INSTALACIONES 12 CORNER BATHS CUTOUT...

Page 15: ...ebajo Es necessario soportar la tina como se explica arriba Los dos lados de una uni n o empalme del contrapiso deben estar nivelados entre s Cuando fije las tinas al muro utilizando pesta as use plan...

Page 16: ...h opening for cooling the motor and to supply sufficient air for the jets Registros En el caso de instalaciones parcial o totalmente empotradas deje un acceso a las conexiones Es responsabilidad del i...

Page 17: ...SHOCK Connect only to a circuit protected by a Ground Fault Circuit Interrupter CAUTION Operating the motor pump without enough water in the bath can cause leaking and permanent damage to the pump Bef...

Page 18: ...nnections of water supply fittings and piping fill systems or drain overflow sys tems Nor is it responsible for damage to the bath which occurs during installation CAUTION A nonflammable protective ba...

Page 19: ...begin when the timer is correctly set it is necessary to push the Magic Touch switch button WATER RAINBOW FILL SPOUT OPTIONAL CASCADA DE WATER RAINBOW OPCIONAL MAGIC TOUCH WHIRLPOOL ON OFF SWITCH INTE...

Page 20: ...relSistemaHidroterape tico El funcionamiento del sistema hidroterape tico de la tina lo determinan tres factores direcci n del flujo fuerza del agua y fuerza del aire Todas las tinas fabricadas por Ja...

Page 21: ...posici n OFF Deje la tina funcionando de 5 a 10 minutos Desag e la tina completamente y vu lvala a llenar s lo con agua fr a Active el sistema hidroterape tico de 5 a 10 minutos y despu s vac e la tin...

Page 22: ...AMP dedicated circuit with GFCI protection With a 8 solid copper wire bond the heater to the house electrical panel or approved local bond A bonding lug is provided on the heater At initial start up a...

Page 23: ...eseada de la perilla del termostato no ser necesario cambiar ni reajustar nuevamente el termostato durante el funcionamiento normal del calentador a menos que decida tener una temperatura diferente In...

Page 24: ...de compliance prior to installation of the product Jacuzzi Whirlpool Bath makes no representation or warranty regarding and will not be responsible for any code compliance LAS ESPECIFICACIONES DEL PRO...

Page 25: ...mo rel mpagos inundaciones terremotos etc Ademas la COMPA A NO SER RESPONSABLE POR DA OS INCIDENTALES O CONSECUENCIALES o p rdidas que se deriven de cualquier causa v g da o del agua a las alffombras...

Page 26: ...t Creek California 94596 Llame a 800 288 4002 Para obtener un reemplazo seg n la garant a para componentes instalados de f brica para opciones abastecidos por la Compa a y accesorios fabricados y abas...

Page 27: ...TIAL DAMAGES or losses arising from any cause e g water damage to carpet ceiling loss of use etc including its own negligence damages to respecting or resulting from plated parts when pool and or spa...

Page 28: ...reek California 94596 Call 1 800 288 4002 Toobtainwarrantyreplacementforfactory installedcomponentsforCompanysuppliedoptionsandaccessoriesmanufacturedandsuppliedbytheCompany callorwrite the above Prov...

Reviews: