background image

English

Page 2 

www.jacuzzi.com

 

Safety Instructions

Arga™ Bathtubs

Safety Instructions

INSTRUCTIONS PERTAINING TO A RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS.

This is a professional grade product. A knowledge of construction techniques, plumbing and electrical installation according to 

codes are required for proper installation and user satisfaction. We recommend that a licensed contractor perform the installation 

of all Jacuzzi Luxury Bath products. Our warranty does not cover improper installation related problems.

 

CAUTION

: When using this unit, basic precautions should always be performed, including the following:

 

READ AND FOLLOW ALL INSTRUCTIONS. SAVE THESE INSTRUCTIONS

 

• 

Use this unit only for its intended use as described in this manual. Do not use attachments not recommended by the  

 

 manufacturer.

 

• 

Never drop or insert any object into any opening.

 

WARNING: RISK OF ACCIDENTAL INJURY OR DROWNING!  

Do not permit children to use this unit unless they are closely supervised at all times. Do not use hydromassage bathtub 

unless all suction guards are installed to prevent body and hair entrapment. Never operate the hydromassage bathtub if the 

suction cover is broken, damaged or missing.

 

DANGER: RISK OF SEVERE INJURY FROM ELECTRIC SHOCK OR DEATH FROM ELECTROCUTION! 

This unit must be connected only to a supply circuit that is protected by a 15 amp ground fault circuit interrupter (GFCI). 

Such a GFCI should be provided by the installer and should be tested on a routine basis. To test the GFCI, push the test 

button. The GFCI should interrupt power. Push the reset button. Power should be restored. If the GFCI fails to operate 

in this manner, the GFCI is defective. If the GFCI interrupts power to the bathtub without the test button being pushed, a 

ground current is flowing, indicating a possibility of an electric shock. Do not use this hydromassage bathtub. Disconnect the 

hydromassage bathtub and have the problem corrected by a qualified service representative before using.

 WARNING: RISK OF ELECTRIC SHOCK!  

Connect only to a circuit protected by a ground fault circuit interrupter (GFCI). (For permanently connected units) A green-

colored terminal (or a wire connector) marked “G,” “GR,” “GROUND,” or “GROUNDING”) is provided within the terminal 

compartment. To reduce the risk of electric shock, connect the terminal or connector to the grounding terminal of your 

electric service or supply panel with a conductor equivalent in size to the circuit conductors supplying the equipment.

 

CAUTION: 

This equipment is intended for indoor use only. Install the equipment in accordance with these instructions. Use 

supply wires that are suitable for 167°F (75°C), including the temperature rating of the supply conductors to be used. This 

unit should be electrically grounded and installed by a licensed contractor, electrician, and plumber. Building materials and 

wiring should be routed away from the motor/pump or blower or other heat producing components of this unit. A pressure 

wire connector is provided on the exterior of the motor/pump and heater to permit connection of an No. 8 AWG solid copper 

bonding conductor between this unit and all other electric equipment and exposed metal in the vicinity, as needed to comply 

with local requirements.

Important CSA Safety Instructions (Canadian models only)

  When using this electrical equipment, basic safety precautions should always be followed, including the 

 following:

 

1.   WARNING: RISK OF ACCIDENTAL INJURY OR DROWNING! CHILDREN SHOULD NOT USE HYDROMASSAGE  

 

 

BATHTUB WITHOUT ADULT SUPERVISION.

 

2.  WARNING: RISK OF ACCIDENTAL INJURY OR DROWNING! DO NOT USE HYDROMASSAGE  

 

 

 

 

BATHTUB UNLESS ALL SUCTION GUARDS ARE INSTALLED TO PREVENT BODY AND HAIR ENTRAPMENT.

 

3.  WARNING: TO AVOID INJURY, EXERCISE CARE WHEN ENTERING OR EXITING THE HYDROMASSAGE    

 

 BATHTUB.

 

4.  WARNING: RISK OF ACCIDENTAL INJURY OR DROWNING! DO NOT USE DRUGS OR ALCOHOL BEFORE OR  

 

 

DURING THE USE OF A HYDROMASSAGE BATHTUB EQUIPPED WITH A HEATER TO AVOID  

 

 

 

 

UNCONSCIOUSNESS AND POSSIBLE DROWNING.

 

5.  WARNING: RISK OF FETAL INJURY! PREGNANT OR POSSIBLY PREGNANT WOMEN SHOULD CONSULT A  

 

 

PHYSICIAN BEFORE USING A HYDROMASSAGE BATHTUB EQUIPPED WITH A HEATER.

 

6.  WARNING: RISK OF HYPERTHERMIA AND POSSIBLE DROWNING: DO NOT USE A HYDROMASSAGE BATHTUB  

 

 

EQUIPPED WITH A HEATER IMMEDIATELY FOLLOWING STRENUOUS EXERCISE.

 

7.   SAVE THESE INSTRUCTIONS.

Summary of Contents for Arga Swirlpool

Page 1: ...eaning Systems Clean 7 Suction Cover Strainer Maintenance 7 Bathtub Additives 8 Filter Basket Maintenance 8 J6 Control Panel Swirlpool System Reference Illustration 8 Gloss Bathtub Care Cleaning 9 Glo...

Page 2: ...d by a ground fault circuit interrupter GFCI For permanently connected units A green colored terminal or a wire connector marked G GR GROUND or GROUNDING is provided within the terminal compartment To...

Page 3: ...omen should consult a physician before using a hydromassage bathtub equipped with a heater WARNING The use of alcohol drugs or medication can greatly increase the risk of fatal hyperthermia People usi...

Page 4: ...esting procedure 1 Remove bathtub from skirt and place on a level surface near appropriate water supply and water drainage A driveway is a suitable choice 2 Seal the drain and overflow hole with tape...

Page 5: ...ll components to the brass tailpiece as shown Fig 3a B Cut the brass tailpiece to length Install components to the brass tailpiece as shown Fig 3b 4 Glue the brass tailpiece assembly to the direct dra...

Page 6: ...n to avoid damage to the brass tailpiece Install your bathtub filler according to the manufacturer s directions included with the purchased filler sold separately Fig 7 Turn power supply on for GFCI p...

Page 7: ...stem it is recommended that Swirlpool bathtubs be cleaned at least twice a month For best results we recommend that you clean your tub after each use using Systems Clean our exclusive two part plumbin...

Page 8: ...ystem and may cause false reading of the water level sensors If excess accumulations persist you should discontinue use of these products After each use remove rinse the filter basket to remove any re...

Page 9: ...htub Care Cleaning Gloss Bathtub Surface Repair Operation Maintenance Instructions Matte Bathtub Care Cleaning Matte Bathtub Surface Repair Troubleshooting Procedures PROBLEM PROBABLE CAUSES REMEDY Pu...

Page 10: ...omatically To stop the function earlier if preferred simply touch the button again The Arga is specifically designed to allow for the use of Jacuzzi Epsom Salts through the integrated salt infuser The...

Page 11: ...can be turned off if desired by touching the button again Note After the waterfall is turned off the salt infuser will slowly drain into the tub As such adding salt to the infuser after the waterfall...

Page 12: ...Page 12 www jacuzzi com Arga Bathtubs English Notes...

Page 13: ...Jacuzzi Luxury Bath 14525 Monte Vista Avenue Chino California 91710...

Page 14: ...oduct Features Brand Name Price Hydrotherapy Home Resale________________________ Other______________________________ 4 Who finally decided which product you would buy Self Spouse Self and Spouse Toget...

Reviews: