50
X
(AL4_1) Electric wiring box memory fault.
It is not possible to store the number of "scale removal cycles”.
HOME SPA model:
the “alarm”, “tepidarium”, "hammam" and "calidarium" keys flash from
white to blue.
BASE AND DREAM model:
not available
X
(AL5) Drainage solenoid valve and/or level sensor fault.
This may occur during the initial phase of the Turkish bath, if the sensor is blocked or if
the drainage solenoid valve is obstructed; it may also occur during the draining phase
of the scale removal cycle.
HOME SPA model:
the “alarm” and "hammam" keys flash from white to blue.
BASE AND DREAM model:
the "hammam" key flashes from white to blue for 3 seconds.
The function (Turkish bath or scale removal cycle) is interrupted.
X
(AL6) Filling solenoid valve and/or level sensor fault.
This may occur during the initial phase of the Turkish bath or during the function. The
cause may be a blocked sensor, an obstructed filling solenoid valve or lack of water.
It may also occur during the final draining phase of the scale removal cycle.
HOME SPA model:
the “alarm” and "calidarium" keys flash from white to blue.
BASE AND DREAM model:
the "hammam" key flashes from white to blue for 60 seconds.
The function (Turkish bath or scale removal cycle) is interrupted.
X
(AL7) Temperature not reached in the shower unit.
This may occur during the Turkish bath, due to a faulty heating element. Or, if the initial
temperature is lower than 25 °C and the function is active for 5 minutes, the probe does not
measure a temperature increase of at least 5 °C (e.g. the shower unit door is open).
BASE-DREAM-HOME SPA model:
the “alarm” key flashes from white to blue.
X
(AL13) Activation of the safety thermostat
.
This may occur during the Turkish bath.
HOME SPA model:
“alarm” and “tepidarium” keys flash from white to blue for approx. 5
seconds and it will not be possible to start the function; if instead the alarm appears when
the function is in progress, it will be interrupted.
BASE AND DREAM model:
the "Turkish bath" key flashes from white to blue for approx. 7
seconds; it will not be possible to start the function; if instead the alarm appears when the
function is in progress, it will be interrupted.