10
10
NOTE:
each sequence begins gradually then, after a few seconds,
reaches its characteristic intensity.
The individual colours:
- white;
- turquoise;
- green;
- orange;
- violet.
To move from one colour to the next, or to change the se-
quence, repeatedly press the
button.
Where the water level in the tub is below that required for
hydromassage, the light will function at reduced power.
IT IS also possible to turn on the light when the tub is empty, us-
ing it as a courtesy light (the light will function at reduced power
in this context too).
SANITIZATION
We recommend the J-MX 07 liquid, offered by Jacuzzi and available
at the Assistance Centres/Authorised Retailers, is used to clean the
tub hydraulic circuit (approximately once a month dependent on
how often the hydromassage is used).
IT IS possible to carry out this cleaning operation using the
same water used for the hydromassage provided that soap, oils,
cosmetics,have not been used; otherwise, empty the tub and fill it
once again.
In any case, the tub water level (free of concentrates) must be ap-
proximately 5-6 cm above the highest jets.
models without sanitization system
Pour 50-100 ml of J-MX 07 liquid into the tub.
Activate the hydromassage for just over 1 minute; leave the
liquid to act for at least a further 15 minutes.
Open the drain and empty the tub.
models with sanitization system
Pour the J-MX 07 liquid from the bottle into the relevant tank
(remove the cover on the tub edge,
4
).
Keep the
key pressed down for a few seconds: the pump
will activate, the spotlight will flash and the sanitization cycle
will commence.
NOTE:
with some models, you have to press keys
and
at the
same time to activate the sanitization cycle.
Once the function has ended, the pump stops and the spot-
light flashes once again.
NOTE:
the cycle is, by nature, automatic and is characterised by the
activation and disabling of the pump and the flashing of the spot-
light at low intensity; in any case, the sanitization cycle lasts 10 min-
utes - approximately 1 minute before the end of the cycle, the pump
is activated once again in order to rinse the pipes and the spotlight
briefly flashes to indicate the end of the function.
The sanitization process cannot be interrupted unless the pow-
er is disconnected via the main switch.
TROUBLESHOOTING...
The hydromassage does not activate
- Check that the main switch is on.
- Press down on the button for a few seconds and then release it.
- The water level is not adequate (when attempting to activate
the function, the light briefly flashes).
Fill the tub to the level indicated (refer to the Chapter, “Hydromas-
sage”) and press the button once again.
The hydromassage stops of its own accord
- In the instance that the water falls below the minimum level
(e.g. open drain), the pump stops (the light, where on, will begin
functioning at reduced power).
Fill the tub to the level indicated (refer to the Chapter, “Hydromas-
sage”) and press the button once again.
Not many air bubbles come out of the larger hydromassage
outlets
- Check that the nozzles are open (refer to the Chapter, “Hydro-
massage”).
The “strength” of the hydromassage has got weaker
- Check that the nozzles are open (refer to the Chapter, “Hydro-
massage”).
- Clean the air and hydromassage outlets (refer to the Chapter,
“Maintenance”).
The Sanitization cycle does not activate
- The water level is too low (consult the information provided
relative to hydromassage.
- The relevant liquid (J-MX 07) is not in the tank (the spotlight
flashes red).
Refill the tank within one minute from notification (the pump will
activate and the cycle continues); where this is not completed, the
cycle is definitely interrupted.
The Sanitization cycle stops of its own accord
- The water has fallen below the minimum level (e.g. drain open);
the spotlight flashes red.
Restore the water level within 5 minutes from notification (the
pump will activate and the cycle continues); where this is not com-
pleted, the cycle is definitely interrupted.
- The J-MX 07 liquid runs out during intake of the hydraulic cir-
cuit; the spotlight flashes red.
Refill the tank within 5 minutes from notification (the pump will
activate and the cycle continues); where this is not completed,
the cycle is definitely interrupted, whilst the spotlight continues to
flash for approximately one hour, indicating that sanitization has