installation / oPeration instrUCtions

installer

:  Leave this manual for homeowner.

Homeowner

:  Read this manual and keep for future reference.

Also find mAnuAl on-line At JAcuzzi.com

copyright © 2007 by Jacuzzi Whirlpool Bath 

fl61000B • october 2007

save these instructions for Future Use.

Complete and mail in the product registration card provided with your unit. 

Write and save the model and serial number of your unit below. 

Owner's Record 

Date Purchased   _________________________________________________________

Purchased From  _________________________________________________________

Installed By  _____________________________________________________________

Serial Number  ___________________________________________________________

Model __________________________________________________________________ 

Summary of Contents for Finestra FL61000

Page 1: ...nd mail in the product registration card provided with your unit Write and save the model and serial number of your unit below Owner s Record Date Purchased_ _________________________________________________________ Purchased From__________________________________________________________ Installed By______________________________________________________________ Serial Number_______________________...

Page 2: ... from the motor pump or blower or other heat producing components of this unit A pressure wire connector is provided on the exterior of the motor pump and heater to permit connection of an No 8 AWG 8 4 mm solid copper bonding conductor between this unit and all other electric equipment and exposed metal in the vicinity as needed to comply with local requirements Warning This unit must be connected...

Page 3: ... heater immediately following strenuous exercise Warning Do not operate this unit without the guard over the suction fitting Warning Keep body and hair a minimum of 6 152 mm away from suction fitting at all times when the hydromassage system is operating Hair longer than shoulder length should be secured close to the head Warning Do not tamper with user operated controls or such devices Warning Us...

Page 4: ... Panel Operation 15 Proper Door Closure 17 Rapid Heat 17 Vacuum Pressure Switch 17 High Limit Switch 17 Pro3 Ozone Sanitation System 18 Maintenance 19 Cleaning the Bath 19 Repairs to the Surface 19 Bath Additives 19 Purging the Whirlpool System 19 Systems Clean Instructions 19 Ozone Maintenance 19 Suction Intake Cover Strainer Maintenance 20 Airbath Interconnection Diagram 21 Whirlpool Bath Interc...

Page 5: ...lation the bath must be filled with water and operated to check for leaks that may have resulted from shipping damage or mishandling Jacuzzi Whirlpool Bath is not responsible for any defect that could have been discovered repaired or avoided by following this inspection and testing procedure Add 1 4 to this dimension when roughing in for 3 wall niche FOR ALL UNITS Electrical Service Requirements A...

Page 6: ...HANGE WITHOUT NOTICE Ordering Information Product Code EU50 Finestra 6030 Walk In 14 Seat Whirlpool Bath LH EU55 Finestra 6030 Walk In 14 Seat Whirlpool Bath RH EY10 Finestra 6030 Walk In 17 Seat Whirlpool Bath LH EY15 Finestra 6030 Walk In 17 Seat Whirlpool Bath RH EV85 Finestra 6030 Walk In 14 Seat Bath LH EV90 Finestra 6030 Walk In 14 Seat Bath RH EY00 Finestra 6030 Walk In 17 Seat Bath LH EY05...

Page 7: ...Y ARE SUBJECT TO CHANGE WITHOUT NOTICE Ordering Information Product Code EW05 Finestra 6030 Walk In 14 Seat Salon Spa Bath Left Hand EW10 Finestra 6030 Walk In 14 Seat Salon Spa Bath Right Hand EY30 Finestra 6030 Walk In 17 Seat Salon Spa Bath Left Hand EY35 Finestra 6030 Walk In 17 Seat Salon Spa Bath Right Hand Left and Right Hand drain locations Standard drain kit No FB48827 Accessories Hardwar...

Page 8: ...NOTICE Ordering Information Product Code EV95 Finestra 6030 Walk In 14 Seat Pure Air Bath Left Hand EW00 Finestra 6030 Walk In 14 Seat Pure Air Bath Right Hand EY20 Finestra 6030 Walk In 17 Seat Pure Air Bath Left Hand EY25 Finestra 6030 Walk In 17 Seat Pure Air Bath Right Hand Left and Right Hand drain locations Standard drain kit No FB48827 Accessories Hardware Remote Drain Kit FC30XXX Pillow EK...

Page 9: ...HOUT NOTICE Ordering Information Product Code EU60 Finestra 6036 Walk In 14 Seat Whirlpool Bath LH EU65 Finestra 6036 Walk In 14 Seat Whirlpool Bath RH EY50 Finestra 6036 Walk In 17 Seat Whirlpool Bath LH EY55 Finestra 6036 Walk In 17 Seat Whirlpool Bath RH EW15 Finestra 6036 Walk In 14 Seat Bath LH EW20 Finestra 6036 Walk In 14 Seat Bath RH EY40 Finestra 6036 Walk In 17 Seat Bath LH EY45 Finestra...

Page 10: ... ARE SUBJECT TO CHANGE WITHOUT NOTICE Ordering Information Product Code EW35 Finestra 6036 Walk In 14 Seat Salon Spa Bath Left Hand EW40 Finestra 6036 Walk In 14 Seat Salon Spa Bath Right Hand EY70 Finestra 6036 Walk In 17 Seat Salon Spa Bath Left Hand EY75 Finestra 6036 Walk In 17 Seat Salon Spa Bath Right Hand Left and Right Hand drain locations Standard drain kit No FB48827 Accessories Hardware...

Page 11: ...T NOTICE Ordering Information Product Code EW25 Finestra 6036 Walk In 14 Seat Pure Air Bath Left Hand EW30 Finestra 6036 Walk In 14 Seat Pure Air Bath Right Hand EY60 Finestra 6036 Walk In 17 Seat Pure Air Bath Left Hand EY65 Finestra 6036 Walk In 17 Seat Pure Air Bath Right Hand Left and Right Hand drain locations Standard drain kit No FB48827 Accessories Hardware Remote Drain Kit FC30XXX Pillow ...

Page 12: ...cause of the design of the bath environment and having full understanding that in this case it may be necessary to remove the unit for service If this is the case diagnosing a problem may not be possible without complete access to the plumbing system This would necessitate the removal of the unit Although this practice is not commonly implemented it is an acceptable method If service access has no...

Page 13: ...cted Danger Risk of electric shock Connect only to a circuit protected by a dedicated Ground Fault Circuit Interrupter GFCI Caution Operating the motor pump without enough water in the bath can cause leaking and permanent damage to the pump Before power is applied to the installation make sure the switch is in the OFF position to avoid pump damage It is necessary to install separate dedicated GFCI...

Page 14: ... Nor is it responsible for damage to the bath which occurs during installation CAUTION A nonflammable protective barrier must be placed between soldering work and bath unit to prevent damage to the bath Shower Information Because of the Walk In baths unique design a rigid shower door cannot readily be installed If a shower is desired we recommend a hand held shower be installed in conjunction with...

Page 15: ...of the water flow swivel the jet nozzle to the desired angle The jets can be directed individually toward any location on your body to provide a hydromassage The jets can also be adjusted so that they all point in the same direction clockwise or counterclockwise to circulate the water in a circular motion around the bath causing a total whirlpool effect Water Force The high volume fully adjustable...

Page 16: ... OFF the pump motor To change speeds use the Toggle buttons Pump Motor Status LED When the pump motor is ON at HIGH speed all four LED indicator lights will be lit When the pump motor is ON at LOW speed the bottom LED indicator light will be lit Left Air Valve Switch Pressing this button will activate the left air valves using the Toggle buttons to increase decrease air flow to the left set of jet...

Page 17: ...air channels NOTE When switching between functions the LED for the inactive functions will dim and the active function will brighten The rubber strip with a double seal will prevent leakage and also provide a visual check before filling the bath with water The figure shows the rubber strip in a fully closed position The view shows the rubber seal from the top NOTE The rubber strip has a double sea...

Page 18: ...and continuously NOTE A soft noise is produced by the pump during operation of the equipment To Set Timer Determine the best time for the ozone generator to operate The ozone generator should be programmed to operate when the air bath is not in use Six hours before use interrupt the power to the air bath at the dedicated GFCI circuit breaker Be sure to observe all safety precautions When the dedic...

Page 19: ... Systems Clean Instructions Refer to the instructions on the Systems Clean packet CAUTION Do not use while bathing Use extreme caution when handling this product Immediately after bathing and exiting the whirlpool bath leave the bath water in the tub and add more hot water The water level in the tub must be at least 2 5 08 cm above the highest jet NOTE Inducted air from the hydromassage system wil...

Page 20: ... cover strainer before reinstalling onto the suction fitting CAUTION Keep hair a minimum of 6 inches 15 2 cm away from the suction intake fitting at all times when the whirlpool system is operating Hair longer than shoulder length should be secured close to the head or a bathing cap should be worn Do not operate the whirlpool system with the suction intake cover removed It is a safety device and m...

Page 21: ...fficient and safe operation If the equipment is not configured as shown in the figure the equipment may not operate or it may result in damage to the equipment MODEL NUMBERS EV95 EW00 EW25 EW30 EY20 EY25 EY60 and EY75 See Specifications for details ELECTRICAL SPECS Requires a separate dedicated GFCI protected circuit Blower 115 VAC 15 A 60 Hz B C A E D LEGEND A Water sensors B Blower C Ozone syste...

Page 22: ...ipment is not configured as shown in the figure the equipment may not operate or it may result in damage to the equipment B C A E F D LEGEND A Heater B Pump motor C Control panel D Control box E Chromatherapy light F Electronic air switch G GFCI Plug 20 A H Ozone system H G MODEL NUMBERS EU50 EU55 EU60 EU65 EY10 EY15 EY50 and EY55 See Specifications for details ELECTRICAL SPECS Requires a separate...

Page 23: ...lt in damage to the equipment I Fuse box J RapidHeat K Electronic air switch L Water sensors PLug into separate dedicated GFCI receptacle Plug into separate GFCI protected breaker C D A F G E I J K L B H LEGEND A Blower B GFCI Receptacle 15 A C Ozone system D Control panel E Pump motor F Chromatherapy light G Control box H GFCI Plug 230 V 20 A MODEL NUMBERS EW05 EW10 EW30 EW35 EW40 EY30 EY35 EY70 ...

Page 24: ...en tightening union nuts hand tighten only Pump motor shuts off by itself before set time elapses Motor thermal protection has deactivated pump motor due to overheating Supply voltage low Let motor cool thermal protection will reset Check for proper ventilation Check supply voltage Dedicated GFCI tripped Reset dedicated GFCI If it continues to trip do not use this unit Disconnect the unit and have...

Page 25: ...om pdf AFC PDF Repair Parts or Accessories visit http jacuzzi com pdf MPD PDF When requesting service or technical assistance please have available both the model and serial number of your unit This information can be obtained from the product registration card provided with your unit If the card has been misplaced this information can be obtained from the specification serial number label on the ...

Page 26: ...Jacuzzi Whirlpool Bath Finestra Walk in Bath Page 26 FL61000B 10 07 THIS PAGE INTENTIONALLY LEFT BLANK ...

Page 27: ...arranty which may have a longer duration than this limited warranty Please confirm with the manufacturer the duration of the appropriate warranty for Options and Accessories WARRANTY LIMITATIONS Our limited warranty does not cover defects damage or failure caused by the common carrier installer user or other persons pets or rodents or resulting from without limitation any of the following careless...

Page 28: ... or Company representative has been permitted to inspect the unit during regular business hours within a reasonable time after the problem was reported by the user In order to obtain warranty service contact the nearest Jacuzzi Whirlpool Bath Authorized Service Agent http www jacuzzi com trade bath_product_ support repairs for listing Describe the problem and the Authorized Service Agent will insp...

Reviews: