b. Remove the screws holding the lower finger boards to the lower terminal.
c. On the wires connecting to the board on the left, it’s easy to mix up the wires.
So note which wires go to which connection. It would make sense to label the
wires. Typically I try to keep these wires in place. Disconnect the rest of the board
connections and swing the board out and to the left. Install new board. Then I can
disconnect wire by wire from old to new board.
d. Unplug the transformer wire to the board.
e. Unplug the pressure switch and both sensor wire connections to the board.
Disconnect topside plug from the side of the control box.
e. Remove screws holding board to control box. Your board might be held to the
control box by nylon posts. To release the board from the nylon post: there is a
clip on the post. Press the clip toward the middle of the post and pull the board
toward you. Do this for all posts and the board will release. To install, reverse.
NOTE HOW TO CONFIGURE NEW BOARD DISCUSSED ABOVE.
Reverse to install.
19