J-100
8. For Australia/ New Zealand, the spa should be supplied through
a residual current device (RCD) with a rated tripping current not
exceeding 30mA (IEC 60335-2-60).
9. To gain access to the spa’s power terminal block, remove the screws
securing the synthetic cabinet panel under the control panel (Figure
A). Then remove the four control box door screws and door (Figure B).
10. Select the power supply inlet you want to use (Figure A). Feed power
cable to control box, then install it through the large opening provided
in the bottom side of the box.
11. Connect wires, color to color, on terminal blocks TB1 and TB3
(Figure C, page 16). TIGHTEN SECURELY! All wires must be
hooked up securely or damage could result.
12. Install control box door and screws and reinstall the cabinet side
panels.
Figure A
Equipment Area
Note: Equipment location (such as pumps, drain, heater etc.) varies by model.
1. Control Box
5.
Pump Drain Plug
2. Power Supply Inlet(s) 6.
1-Speed Pump
3. 2-Speed Pump
7.
Control Panel
4. Heater
3
6
2
2
5
5
1
4
7
Figure B
Control Box
TB1
3
2
1
1. Terminal Block
2. Bonding Lug
3. Grounding Terminal
15