19
Avoid using these substances before getting into the spa.
Do not use a spa immediately following strenuous exercise.
Be very careful when getting in an out of the spa. All of the
surfaces are slippery when wet.
The spa is not intended for use in public places; always check
for any restrictions and/or regulations concerning the installa-
tion and use of the apparatus in the area chosen.
Electrical safety
The spa are safe products, manufactured in compliance with
standards
EN 60335-1, EN 60335-2-60, EN 12764
and tested dur-
ing production to ensure user safety.
Installation must be performed by qualified personnel who
ensure compliance with current national regulations and who
are also authorized to issue a certificate of compliance with
proper installation procedures.
It is the responsibility of the installer to select materials
based on their intended use, to carry out work properly,
to check the condition of the system that the unit will
be connected to and that it ensures safety of use also
concerning maintenance work and the possibility to ex-
amine the system.
The spa are class “
I
” appliances and therefore they must be
permanently connected,
without any intermediate connec-
tions
, to the electrical system and to the protection system
(earth system).
The electrical system of the building must be provid-
ed with a 0.03A differential switch and with an effi-
cient protection (earth) circuit. Check for proper op-
eration of the differential switch by pressing the TEST
button, which should trip.
Parts incorporating electrical components, except
remote control devices, must be located or fixed so
that they cannot fall into the spa. Live components
and equipment must be out of reach of individuals
in the spa.
For connection to the electrical mains, it is necessary to install
an omnipolar cut-off switch as per the values indicated in the
chapter “Electrical characteristics., which is to be located in an
area which is compliant with safety instructions and which can-
not be reached by the users who are using the spa.
It is manda-
tory to comply with this instruction. Any other procedure is prohib-
ited.
The installation of electrical devices and equipment (sockets,
switches, etc.) near the spa must be in compliance with legal
standards and regulations in the country where the spa is
installed.
The disconnection devices must be installed in the power
supply network according to the installation instructions.
For the equipotential connection as required by specific
national standards, the installer must use the terminal provided
(standard
EN 60335.2.60
) in the electrical box, and marked
with the symbol
. In particular, an equipotential condition
must be established for all metallic masses surrounding the spa,
for example water and gas pipes, metallic platforms, and so on.
Refer to the pre-installation information sheet for instruc-
tions and electrical input of the various models.
Start-up instructions
Read each step in its entirety before proceeding with that
step.
Remove any dirt from the spa. Although the spa shell has
been polished at the factory, you may want to treat it with a
specially formulated spa cleaner and wax available from your
dealer prior to filling the first time.
Filling the spa
Remove the filter cover and the filter cartridge as indicated in
the chapter on cleaning the filter.
Position the end of the hose inside the filter connection and
fill the spa until the level of water covers all of the nozzles,
without however reaching the headrest.
Do not overfill your mini-pool.
N.B.:
If your water is extremely hard, it is preferable to fill halfway
with hard water and the rest of the way with softened water.
Always fill the mini-pool from the filter fitting so as to expel
air trapped in the pump intake. Otherwise, the air may re-
main in the nozzle of pump, preventing the pump from cir-
culating the water.
After filling, make sure the filter is installed properly before ap-
plying power to the mini-pool (refer to the chapter on clean-
ing the filter).
Checks
Open the cabinet access panel and check all pump fittings to
make sure they are tight. Loosening can occur during shipping
and handling.
Turning on power
Turn on power to spa at the home’s circuit breaker: the heater
and pump automatically activate. The water temperature LED
flash on the control panel and the messages “COL” or “ICE” ap-
pear.
NOTE:
“COL” and “ICE” will only appear when the spa is in E-
conomy mode.
Start-up
Activating the pump(s)