14
J-300
export J-335, J-345, J-355, J-365 and J-375 Models (50 hz)
230V/20A*
230V/30A**
230V/40A***
Circuit Breaker:
20A
30A
40A
Number of Wires:
3
3
3
Frequency:
50 Hz
50 Hz
50 Hz
Current Draw:
15A
23A
29A
*
In 20A configuration, the heater
will not operate
while either jets
pump is running in high speed.
This is the factory setting. Note:
pump 2 runs only in high speed.
**
In 30A configuration, the heater
will operate
while one jets pump
is running in high speed.
Note: pump 2 runs only in high speed.
***
In 40A configuration the heater
will operate
while both jets pumps
are running in high speed.
export J-315 and J-325 models (50Hz)
230V/20A*
230V/30A**
Circuit Breaker:
20A
30A
Number of Wires:
3
3
Frequency:
50 Hz
50 Hz
Current Draw:
15A
21A
In 20A configuration, the heater while the jets pump is running in
high speed.
This is the factory setting.
In 30A configuration, the heater while one jets pump is running in
high speed.