19
J-300 series
J-300 Series
5.
add start-up Chemicals
Add the spa water chemicals as recommended by your authorized
Jacuzzi dealer. See Section 13.0 “Water Quality Maintenance” (page
for general guidance.
warnInG:
rIsK oF poIsonInG or DeaTH.
Never leave chemicals opened and accessible to anyone. Use
chemicals according to the vendors instructions. Always store
chemicals in a safe and/or locked location. Keep away from
and out of reach of children.
!
6.
establish a stable sanitizer reading
Establish a stable sanitizer reading between 3.0-4.0 ppm chlorine or 2.0-
4.0 ppm bromine. To ensure healthy water conditions, always maintain
a constant sanitizer reading within the levels recommended by the
Association of Pool and Spa Professionals/USA printed on the inside
cover of this manual. If sanitizer levels cannot be stabilized, perform the
decontamination procedure steps 9-16 on pages 2
.
note:
The “decontamination procedure” steps 9-16 should also be used
after the spa has been “Winterized” (Section 12.7 page
) or has been
sitting without power for an extended period.
7.
set spa To Heat
To warm spa water to a comfortable temperature, follow
these steps:
The LED display on the control panel displays the
•
actual temperature of the spa water. Press either the
COOLER ( ) or WARMER ( ) button once to display the “set”
temperature for 5 seconds. If you want the water to heat to a different
temperature, simply press COOLER ( ) or WARMER ( ) within 5
seconds. The set temperature increases or decreases by one degree
each time one of these buttons is pressed.
The heater will turn off when the temperature corresponding to the
•
thermostat setting is achieved.
Important Heater Details:
The maximum water temperature setting for your spa is 104 °F
•
(40 °C) and the minimum setting is 65 °F (18 °C).
For North American spas connected to a 40 amp service, jets pump
•
#1 must be set to low speed and jets pump #2 must be turned off to
operate the heater.
For Export spas connected to a 20 amp service, jets pump #1 must
•
be set to low speed and jets pump #2 must be turned off to operate
the heater.
Setting the thermostat at maximum will not accelerate the heating
•
process. This will only result in a higher ultimate temperature.
The heater operates until the water reaches the programmed “set
•
temperature”, then turns off. The heater will reactivate after the
water cools to approximately 1.5° below the set temperature.