Page 44
J-400 Series
To ensure optimum performance, the 24-hour ProClear™
II skimming filter cartridge (A) must be cleaned every three
months and replaced once a year. The secondary
ProClear™ Plus polishing filter bag (B) should be emptied
weekly and replaced every 3 months. The ProClear™ II
filter cartridge (C) must be cleaned every three months and
replaced once a year. To accomplish this, refer to the
following filter cleaning procedure.
note:
Do not attempt to wash the polishing filter bag (B) or it will come
apart!
DanGer: Turn POwer TO sPa OFF! TO DeCrease rIsK OF
Death, Drowning, or entrapMent, never operate spa when
FIlTer Is nOT PrOPerlY InsTalleD Or IF weIr assemBlY Is
DamaGeD Or alTereD!
A
B
2.
1.
4.
5.
3.
1.
Remove power to the hot tub before removing the skimmer
(A) or filter bag cover (B).
2. Remove the polishing bag lid (B) by rotating it
counterclockwise approximately 5 degrees until you feel it
unlatch.
3. Remove the polishing bag by reaching into the filter bucket
and gently pulling upward on the blue filter ring (empty filter
bag weekly or install a new bag every three months.) Located below
the bag is a small Proclear filter. Remove the filter by rotating it
counterclockwise. For cleaning procedures see step 6 below. Once
the filter has been cleaned or replaced, reinstall it into the skimmer
below the polishing bag. Replace bag, then install filter lid by rotating
it clockwise until you feel it latch in place. DO NOT FORCE LID!
FINGER TIGHT ONLY!
4. Remove the ProClear skimmer assembly (A) by gently lifting upward
from the filter bucket.
5. Remove the ProClear filter cartridge by rotating it counterclockwise
to unthread it, then remove the center cap and chemical dispenser
from the filter cartridge as shown (right).