Page 15
J-400 Series
Export J-460/J-465/J-470/J-480 Models (50Hz)
Voltage:
230 VAC
230 VAC
230 VAC
Max. Current Draw:
16A
21A
29A
Frequency:
50 Hz
50 Hz
50 Hz
Number of Wires:
3
3
3
Circuit Breaker (2-Pole):
20A*
30A**
40A***
*
In 20A configuration, the heater
will not operate
while either jets
pump is running.
**
In 30A configuration, the heater
will not operate
while both jets
pumps are running.
This is the factory setting.
***
In 40A configuration the heater
will operate
while both jets pumps
are running.
8.0 spa Fill up Procedure
For best results, reaD eaCh step in its entirety beFore
PrOCeeDInG wITH THIs PrOCeDure.
1.
Prepare The spa For Filling
•
Clear all debris from the spa. (Although the spa shell has been
polished at the factory, you may want to treat it with a specially
formulated spa cleaner. Consult your authorized Jacuzzi dealer for
additional information prior to filling spa.
•
Remove both ProClear™ Plus skimmer and polishing filter lids and
filters as illustrated in section 13.1 (page 4
).
2.
Fill spa
•
Place the end of your garden hose into empty skimming filter bucket
(filter bucket on your left) as you stand next to the spa. Fill spa half
way, then place the garden hose into the opposite filter bucket (filter
bucket on your right) while adding the remaining fill water.
CauTIOn:
TO DeCrease BuIlD uP On COmPOnenTs anD
mInImIZe aCrYlIC DamaGe.
Never fill with water from a water softener. If your water is
extremely “hard”, it is preferable to fill half-way with hard water and
the rest of the way with softened water. You may fill entirely with
hard water if you use a special water additive available from your
Jacuzzi dealer.