Page 39
J-400 Series
When in a Summer Logic condition is active (see note below), the filter/
circulation pump will turn on for all programmed filter cycles.
summer logic:
In warm weather, the water temperature in the spa
may exceed the set temperature. This condition may occur due to heat
transference from the filter/circulation pump and jets pumps. If the
water temperature is higher than 95°F (35°C) and rises two degrees
above the set temperature, a “Summer Logic” condition occurs that
deactivates the filter/circulation pump and ozonator (if equipped).
This safety feature cannot be altered!
The filter/circulation pump and
ozonator will remain off until the water temperature cools to the set
temperature (except between 9:00 - 11:00 AM when the filter/circulation
pump runs for its mandatory 2-hour cycle). To help prevent a “Summer
Logic” condition, it may be necessary to reduce filter/circulation pump
cycles run times in warm weather.
Programming economy Heating Cycles
To make adjustments, first press the CYCLE
button to enter the
filter cycle programming mode. The LCD screen will display the following
in the upper right corner:
1*
This means the system is ready to accept your changes to the start time
for cycle number one. Simultaneously, the large four-digit display in the
center of the screen displays the currently programmed start time for that
cycle. At this point, you have four options. You may:
1. Press
warmer
or
COOler
button to adjust the start
time in increments of 30 minutes.
2. Press
CYCle
button to display and adjust each subsequent
cycles start time. With each press, the currently programmed status
will be shown in the large four digit display. To adjust any displayed
value, simply press the
warmer
or
COOler
button.
3. Press
seleCT
button to move down the menu from Start Time
to Duration, with each press, the currently programmed duration will be
shown in the large four-digit display. Press
warmer
or
COOler
button to adjust the duration in increments of 15 minutes.
4. Press
DIsPlaY
button to save changes and recall the main
water temperature display.
note:
If no button is pressed within 30 seconds, all changes are
recorded and the screen automatically returns to the standard water
temperature display.
*Note: Number will
vary according to
which filter cycle is
being programmed.