61
J-400
E
Lift unthreaded filter
cartridge from skimmer
well.
Note:
Primary filter
fitting is the one with
the grid.
F
Cartridge 1
If used, remove the
chemical feeder as
instructed prior to rinsing
the filter cartridge. Rinse
debris from filter pleats
using a garden hose and
high-pressure nozzle.
Start at the top and
work downward towards
handle. Repeat until all
pleats are clean.
G
1
Remove the filter pin
1
in order to separate
the ProClarity filter and
canister.
H
1
2
3
Once the filter pin is
removed, rotate the
filter cartridge handle
counterclockwise to
unthread from the filter
canister. You can clean
the filter
1
and canister
3
, but you must replace
the ProClarity Depth
Filter
2
every 3 months.
I
Canister
Cartridge 2
Rinse debris from filter
pleats using a garden
hose and high-pressure
nozzle. Start at the top
and work downward
towards handle. Repeat
until all pleats are clean.
Rinse out any debris
from the canister.
J
1
Reassemble the
ProClarity Filter.
Remember to replace
the depth filter with a
new one. Once the filter
is assembled, secure it
with the filter pin
1
.