72
J-400
11. Reinstall and hand tighten the quartz seal compression nut (5) by
turning it
clockwise
.
12. Refill your spa.
13.
System Test 1:
Assure there is no water dripping from the seal
compression nut (5). If water is visible, STOP and tighten the
compression nut (5) using a pair of channel lock pliers to a maximum
of 1/4 turn. If that does not fix the leak, then repeat quartz tube
maintenance process from step 1 through step 12. Make sure there
is no water leaking before proceeding to step 14.
14.
System Test 2:
Reconnect the CLEAR
RAY
unit to the controller.
Turn breaker back ON. Turn on the pump to circulate the water
through the CLEAR
RAY
System. Wait for 5 minutes and assure no
water is dripping. If water is visible, STOP, fix the leak by repeating
quartz tube maintenance process from step 1 through step 13.
Make
sure there is no water visible. Turn the pump and breaker OFF
BEFORE proceeding to step 15.
15. Reconnect the UV bulb socket (7) to the power cord socket (11)
make sure you use the latex glove provided when handling the UV
bulb.
WARNING:
DO NOT TOUCH THE NEW UV BULB WITH
YOUR BARE HAND.
Oil on your skin will cause hot spot on
the UV bulb and shorten the life of your UV bulb. Use the pro-
vided latex glove to handle the UV bulb.
!
16. Slide the new UV bulb (3) back inside the quartz tube.
17. Reinstall the black bulb boot (6) back over the quartz seal
compression nut (5).
18. Reinstall the enclosure cover (9) with gasket (8) and secure with the
screws.
19. Properly dispose of the old UV bulb.
WARNING:
This CLEAR
RAY
System includes a UV bulb,
which contains mercury. Dispose of the bulb in accordance
with disposal laws. See www.lamprecycle.org.
!
20. Once power is activated you can check the ballast
(12), Figure 8, to see if the CLEAR
RAY
System is
functioning; it has two LED indicator lights the green
indicating incoming power flow and the red indicating the
system is properly working.
120 - 230V
FIGURE 8