12.2 Programming the Primary Filter
To access the “Primary Filter” feature, tap
1
from the Heat & Filter
menu, Figure 12.2a, to enter the “Primary Filter” programming menu,
Figure 12.2b.
During a primary filtration, the circulation pump, CLEAR
RAY
and ozone
unit (if applicable) are activated. The factory default cycle starts at 12:00
AM and last for 8 hours. If you elect to keep this setting, then you can
skip this section.
In extreme bitter cold weather we recommend you pro-
gram the circulation pump to run 24 hours. Refer to the
"Winterizing" section on page 66.
Any time the circulation pump runs outside of a program cycle, e.g. for
heating, that run time will be deducted from the next primary filter cycle.
For example, the primary filter cycle is set to 8 hours every 24 hours but
the circulation pump comes on for 2 hours to heat the water after the
cycle has finished. The next primary filter cycle will only be for 6 hours
not 8 hours.
A.
To change the default cycle:
When you enter the menu, “Start” and “12” will be
highlighted.
1. Tap or to change the hour in 1-hour
increments. To switch from “AM” to “PM” you
must round a 12-Hour period.
2. Tap to accept the change.
3. Tap
End
to program the end time for the
cycle.
4. Tap the hour block to change the end time.
5. Tap or to change the hour in 1-hour increments. To switch from
“AM” to “PM” you must round a 12-Hour period.
6. Tap to confirm and save your changes.
7. Tap
, a couple of times, to return to the Heat & Filter Menu and
the Settings Menu.
Figure 12.2a
Figure 12.2b
Auto
Econo
Day
Filter
2
1
Heat & Filter
Start
End
pm
12
12pm
8pm
Primary Filter
Figure 12.2c
Start
End
pm
12
12pm
8pm