Page 87
J-400
C.
Configuration settings for J415-J480 Models
Single Service (default setting):
1x16A
(J415 Only)
This setting will turn the heater off any time
the jets pump is activated.
1x20A
This setting will turn the heater off any time either one of
the pumps are activated on two pump models.
1x32A
This setting is for all two pump model spas. Both pumps
and the heater will be allowed to operate at the same
time.
Dual Service:
2x16A
(J415 Only)
Both the jets pump and the heater will be
allowed to operate at the same time.
1x16A/1x20A This setting is for all two pump model spas. Both pumps
and the heater will be allowed to operate at the same
time.
Three Phase Service:
3x16A
This setting is for all two pump model spas. Both pumps
and the heater will be allowed to operate at the same
time.
D.
Configuration settings for J495 Models
Single Service (default setting):
1x32A
This setting will allow the heater to operate when two
jets pumps are activated. If all three pumps are activated
the heater will shut off.
1x40A
All three jets pumps and the heater will be allowed to
operate at the same time.
Dual Service:
1x16A/1x32A All three jets pumps and the heater will be allowed to
operate at the same time.
Three Phase Service:
3x16A
All three jets pumps and the heater will be allowed to
operate at the same time.