33
LX Collection
11.6 Programming the CLEARRAY® (Ultraviolet) Water
Purification System
A.
Programming the
CLEAR
RAY System (U) or Corona Discharge
Ozone (O3)
Press and hold the
Jets pump 1
(
1
) and
Cooler
(
) button
at the
same
time for 3 seconds. Scroll pass the circulation pump programming
menus by pressing the Warmer button, Figure 1.
Press
Press
Press
Press
Press
Press
Press
Will take you
back to “C0”
Will select
“O3” option
and exit menu
Press
1
Press
1. After the last cycle, “C6”, the LED screen will display “U” or “O3.”
If the LED screen is displaying “U” then pressing the Jets pump
1 will change the sanitizing system from “U” to “O3” and exit the
programming menu. If the LED screen is displaying “O3” then
pressing the Jets pump 1 will change the sanitizing system from “O3”
to “U” and exit the programming menu. You will see one of the two
configurations below:
A. C0, C1, C2, C3, C4, C5, C6, U, 365 (duration countdown timer)
B. C0, C1, C2, C3, C4, C5, C6, O3, =
Note:
For the O3 option the “=” disables the duration countdown timer.
2. If you do not wish to change the option do not press any buttons and
after 10 seconds the display will return to the main menu.
Note:
If the CLEAR
RAY
System has been selected, when
the time allotted has expired (365 days) the display screen
will flash between the water temperature and “blb.” At this
time the UV bulb must be replaced, the quartz tube must be
cleaned and the duration countdown timer needs to be reset.