44
LX Collection
WARNING:
RISK OF PERSONAL INJURY, DROWNING
OR ENTRAPMENT!
Never leave your hot tub unattended for any reason while
the cover is open and accessible, especially to small children
and animals!
CAUTION: RISK OF PERSONAL INJURY OR SPA DAMAGE!
Never add chlorine tablets (trichlor) or acid to your hot tub
for any reason! These chemicals may damage components
within your hot tub, burn or irritate your skin, create a rash
and void the manufacturer warranty for your spa.
!
13.3 CLEARRAY® (Ultraviolet) Water Purification System
CLEAR
RAY
Water Purification System is exclusive
technology utilizing natural ultraviolet technology to
eliminate waterborne bacteria, viruses, and algae in
portable spas. The ultraviolet light otherwise know as
UV-C or germicidal light inactivates the microorganisms
disrupting the DNA so that it cannot reproduce and is
considered lifeless. CLEAR
RAY
is plumbed inline with your
filtration system. After the water is drawn from the pump, filter,
and heater it is then directed though the CLEAR
RAY
system.
Water passes through an ultraviolet light energy that treats and
disinfects the water. The water is then pumped back into the
spa giving you crystal clear water instantly. The system has a
ballast that is the power supply for the purification system; it
has two LED indicator lights the green indicating incoming power flow
and the red indicating the system is properly working. CLEAR
RAY
is
standard for all models.
Note:
The CLEAR
RAY
System only runs when the circulation pump
is running and shuts off when either jets pump is manually activated
during spa use. The system will remain off for 5 minutes after both jets
pumps time out or are manually turned off, then resume operations if the
circulation pump is programmed to run.
After a year the bulb must be replaced. If the UV timer has been
programmed correctly a message will appear on the LED display when
the time allotted has expired. In order to clear the “blb” message a new
UV bulb needs to be installed and the timer must be reset (Section 11.6,
page 34).
WARNING!
DO NOT LOOK AT LIT BULB
SEVERE EYE DAMAGE
OR BLINDNESS CAN OCCUR
120 - 230V