WARNING!
DONOT LOOK AT LIT BULB
SEVERE EYE DAMAGE
OR BLINDNESS CAN OCCUR
10
4
3
7
1
2
2
11
5
6
8
9
25
Always fill the spa from both filter connections, so as to expel
air trapped in the pumps. Otherwise the air may remain trapped,
preventing the pumps from circulating the water.
After filling, make sure both filters are installed properly before
applying power to the spa. (refer to sec. “Cleaning The Filters”).
Checks
Open the cabinet access panel and check all pump fittings to make sure
they are tight. Loosening can occur during shipping and handling.
Turn on Power
Turn on power to spa from the main switch (refer to the chap-
ter "Electrical safety". The heater and circulation pump will auto-
matically activate.
The flashing of the water temperature icon together with "COOL"
or "ICE" on the display of the control panel may be normal as
the water in the system is often cold; please refer to the "Prob-
lem resolving - Display messages" section.
Startup
Start up the pumps (refer to "Control panel" chapter).
Addition of chemcial additives at first start-up
Please refer to the Jacuzzi system water treatment guide and relative
catalogue for details on water quality maintenance, the methods and
warnings governing the use of relative chemical products.
N.B.:
Always cover the spa
(except during the mixing of the
chemical additives!)
with an isolating cover thus reducing the
heating times and minimising the running costs.
The time necessary for the initial heating varies based on the
start temperature of the water.
WARNING!
Do not get in the spa until the quantity of disinfectant has not
dropped below the level recommended by the manufacturer
and/or by your retailer.
Always check water temperature carefully before entering spa.
Control Panel
A
Display:
can display current water temperature, water tem-
perature set point, selected skimming/heating mode, and error
messages.
B.
( + ) Button:
increases water temperature set point.
C.
( - ) Button:
decreases water temperature set point.
D.
Light On/Off button Options: Turns waterfall, footwell, and
accent lighting on in unison. Press once for high intensity;
press a second time for medium intensity; press a third time
for low intensity; press a fourth time to turn off. The displayed
color is changed using the light mode button (E) below.
E.
Light mode Button: Selects one of 4 color modes for wa-
terfall, footwell, and accent lighting.
F.
Pump 1 button:
turns pump 1 on and off. Press once for low
speed; press a second time for high speed; press a third time to
turn pump off.
G.
Pump 2 button:
turns pump 2 on and off. Press once to turn
it on; press twice to turn the pump off.
The jets operate for 20 minutes after activation; then they switch
off automatically to conserve energy. Simply press either jets
button to continue operation for an additional 20 minutes.
H.
Heat Indicator:
lit when heater is on.
1
2
H
A
D
B C
E
G
F
1
Electrical box
2
Power supply entrance(s)
3
2-Speed Pump
4
Heater
5
Drain valve
6
Pump drain plug(s)
7
1-Speed Pump
8
Circulaiton pump
9
CLEARRAY™ (Ultraviolet) Water Purification
System
10
Electronic Ballast (for the CLEARRAY System)
11
Display
Summary of Contents for J-LXK
Page 2: ... Italiano 03 English 23 Français 42 Index ...
Page 22: ......
Page 62: ......
Page 63: ......